Skip to main content
Door · Wood Frame NFRC JEL · Product Line JEL-N-147

JELD-WEN, inc. — Custom Clad Sliding Door · Sliding Patio Door

With a minimum U-Factor of 0.25—+0.04 compared against the 0.21 Door median—JELD-WEN, inc. Custom Clad Sliding Door spans 67 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code JEL, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.15 and 0.28.

Min U-Factor
0.25
SHGC Range
0.15-0.28
Certified Options
67
Category Standing
#216 of 268

How does JELD-WEN, inc. Custom Clad Sliding Door compare thermally against Door peers?

JELD-WEN, inc. Custom Clad Sliding Door achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Custom Clad Sliding DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Custom Clad Sliding Door (U 0.25).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.25100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Custom Clad Sliding Door Cohort StandingMin U-Factor 0.25 stands at rank #216 of 268, outperforming 13.4% of peers.Min U-Factor 0.25Rank #216 of 268 (13.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 61 certified JELD-WEN, inc. series, this Sliding Patio Door offers a 0.03 U-Factor adjustment span between 0.28 entry options and 0.25 top-performing glazing. Category standing is #216/268 (tied with 16 others at 0.25, more insulating than 13.4% of Door lines).

Mapping NFRC SHGC values (0.15 to 0.28) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 15 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-03-10 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 67 certified glazing combinations for Custom Clad Sliding Door (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 15 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 15 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 60 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 60 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom Clad Sliding Door appear below.

What U-Factor and SHGC range does JELD-WEN, inc. Custom Clad Sliding Door achieve?

Built with Wood framing in Sliding Glass Door (DDSG) style, JELD-WEN, inc. Custom Clad Sliding Door offers 67 Version 7.0 configurations from U 0.25 up to 0.28, posting +0.04 against the Door median of 0.21 with 0 Most Efficient picks.

Is Custom Clad Sliding Door approved for Northern Zone heating climates?

Prescriptive Northern approval ends at U <= 0.22, above Custom Clad Sliding Door's 0.25 minimum. However, 15 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How much winter heat loss does Custom Clad Sliding Door conduct across a 15 sq ft opening?

Using NFRC JEL U-Factor 0.25, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

When should a buyer skip JELD-WEN, inc. Custom Clad Sliding Door and compare alternatives?

Skip Custom Clad Sliding Door if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom Clad Sliding Door options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Custom Clad Sliding Door?

Yes. 60 Southern-certified options inside JELD-WEN, inc. Custom Clad Sliding Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.28 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 67 Custom Clad Sliding Door configurations ENERGY STAR Most Efficient?

Custom Clad Sliding Door holds zero Most Efficient entries across its 67 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Custom Clad Sliding Door?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 JELD-WEN, inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Custom Clad Sliding Door after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.25-0.28, SHGC 0.15-0.28) against permit drawings for line JEL-N-147. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom Clad Sliding Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros