Skip to main content
Door · Wood Frame NFRC MAR · Product Line MAR-N-486

Marvin — Infinity Outswing French Door · Swinging Entry Door (Double)

With a minimum U-Factor of 0.25—+0.04 compared against the 0.21 Door median—Marvin Infinity Outswing French Door spans 144 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code MAR, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.14 and 0.21.

Min U-Factor
0.25
SHGC Range
0.14-0.21
Certified Options
144
Category Standing
#216 of 268

How does Marvin Infinity Outswing French Door compare thermally against Door peers?

Marvin Infinity Outswing French Door achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Infinity Outswing French DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Infinity Outswing French Door (U 0.25).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.25100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Infinity Outswing French Door Cohort StandingMin U-Factor 0.25 stands at rank #216 of 268, outperforming 13.4% of peers.Min U-Factor 0.25Rank #216 of 268 (13.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Infinity Outswing French Door reaches 0.25 on its lowest-conductivity package — #319 of 408 in Wood, tied with 32 others at 0.25, more insulating than 14.0% of Wood lines (+0.04 vs Wood peers). Pairing NFRC ID MAR across multi-pane fills shifts U-Factor from 0.28 down toward 0.25.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 46 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2024-07-02.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 144 certified glazing combinations for Infinity Outswing French Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 46 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 46 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 144 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 144 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Outswing French Door appear below.

How efficient is Marvin Infinity Outswing French Door compared with peer Door models?

Across 144 tested NFRC glazing configurations, Marvin Infinity Outswing French Door with Wood framing and Hinged Patio French Door (DDFR) style reaches a 0.25 minimum U-Factor and 0.14-0.21 SHGC band. It places #216 among 268 Door series—more insulating than 13.4%.

Is Infinity Outswing French Door approved for Northern Zone heating climates?

Because Infinity Outswing French Door starts at 0.25 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 46 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

How much winter heat loss does Infinity Outswing French Door conduct across a 15 sq ft opening?

At U 0.25, a standard 3x5 ft (15 sq ft) Infinity Outswing French Door opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

When should a buyer skip Marvin Infinity Outswing French Door and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Outswing French Door options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Does Infinity Outswing French Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Infinity Outswing French Door holds 144 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

What glazing share inside Infinity Outswing French Door qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 144 Infinity Outswing French Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to Infinity Outswing French Door?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Marvin Infinity Outswing French Door units match permits?

Inspectors match the temporary NFRC sticker (U 0.25-0.28, SHGC 0.14-0.21) against permit drawings for line MAR-N-486. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Outswing French Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)