Skyreach Group Inc. — PD02 Door · Sliding Patio Door
Skyreach Group Inc. PD02 Door is a Sliding Patio Door assembly with a Vinyl frame that reaches a minimum U-Factor of 0.25 across 2 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #216 of 268 in Door, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.21 to 0.21.
- Min U-Factor
- 0.25
- SHGC Range
- 0.21-0.21
- Certified Options
- 2
- Category Standing
- #216 of 268
How does Skyreach Group Inc. PD02 Door compare thermally against Door peers?
Skyreach Group Inc. PD02 Door achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Skyreach Group Inc. PD02 Door at rank #216 of 268 (tied with 16 others at 0.25, more insulating than 13.4% of Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.21-0.21 band.
Climate coverage for Skyreach Group Inc. PD02 Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 1 Northern package qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Data provenance links certification 2025-07-10 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2 certified glazing combinations for PD02 Door (NFRC SGI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 1 package (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 1 package (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 2 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 2 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Specialty Wholesale Supply — 1001/1005/1006 Patio Door | Vinyl | 0.25 | 0.07 | 8 |
| Anlin Industries — Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door | Vinyl | 0.25 | 0.10 | 63 |
| Krestmark Industries L. P. — 900 Sliding Patio Door | Vinyl | 0.25 | 0.15 | 81 |
| Kolbe and Kolbe Millwork Co., Inc — Forgent Complementary Multislide Door | Vinyl | 0.25 | 0.10 | 90 |
| Marvin — Essential Sliding Patio Door | Fiberglass | 0.25 | 0.20 | 36 |
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Skyreach Group Inc. PD02 Door appear below.
How efficient is Skyreach Group Inc. PD02 Door compared with peer Door models?
EPA ENERGY STAR v7.0 records 2 configurations for Skyreach Group Inc. PD02 Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.21 Door median. Only 0 options earn Most Efficient status.
Which glazing options in Skyreach Group Inc. PD02 Door meet Northern climate limits?
Prescriptive Northern approval ends at U <= 0.22, above PD02 Door's 0.25 minimum. However, 1 Northern package pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.
How do you calculate winter heat conduction for Skyreach Group Inc. PD02 Door?
Using NFRC SGI U-Factor 0.25, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).
Which situations make PD02 Door the wrong window or door choice?
Do not specify PD02 Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on PD02 Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Is PD02 Door suitable for sunbelt cooling-dominated homes?
Yes, PD02 Door holds 2 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.21 SHGC in cooling climates.
Are all 2 PD02 Door configurations ENERGY STAR Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 2 PD02 Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What 2026 federal tax credit and Lead RRP rules apply to PD02 Door?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Skyreach Group Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify PD02 Door glass specs on job sites?
Confirm both the paper NFRC label and permanent corner glass etch match line SGI-K-2 and NFRC ID SGI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Skyreach Group Inc. PD02 Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)