Anlin Industries — Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door · Sliding Patio Door
EPA ENERGY STAR Version 7.0 certifies 63 variants inside Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door, combining Vinyl frame construction with U-Factors spanning 0.25 to 0.28 and SHGC 0.10 to 0.37. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #216 of 268 among 268 Door families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.25
- SHGC Range
- 0.10-0.37
- Certified Options
- 63
- Category Standing
- #216 of 268
How does Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door compare thermally against Door peers?
Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door at rank #216 of 268 (tied with 16 others at 0.25, more insulating than 13.4% of Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.10-0.37 band.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 23 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2017-12-11 and cert timestamp 2026-09-16.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 63 certified glazing combinations for Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 23 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 23 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 58 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 58 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Krestmark Industries L. P. — 900 Sliding Patio Door | Vinyl | 0.25 | 0.15 | 81 |
| Kolbe and Kolbe Millwork Co., Inc — Forgent Complementary Multislide Door | Vinyl | 0.25 | 0.10 | 90 |
| Specialty Wholesale Supply — 1001/1005/1006 Patio Door | Vinyl | 0.25 | 0.07 | 8 |
| Skyreach Group Inc. — PD02 Door | Vinyl | 0.25 | 0.21 | 2 |
| JELD-WEN, inc. — Custom Clad Sliding Door | Wood | 0.25 | 0.15 | 67 |
What other certified series does Anlin Industries produce?
Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Coronado/Monte Verde/Bayview/Extreme Fixed Casement
U-Factor 0.22–0.32 · 462 certified options.
Catalina/Del Mar/Extreme Horizontal Sliding Window
U-Factor 0.23–0.32 · 259 certified options.
Catalina/Del Mar/Extreme Single Hung Window
U-Factor 0.23–0.32 · 259 certified options.
Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider
U-Factor 0.23–0.32 · 230 certified options.
Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung
U-Factor 0.23–0.32 · 230 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door appear below.
What thermal performance numbers separate Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door from peers?
EPA ENERGY STAR v7.0 records 63 configurations for Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.21 Door median. Only 0 options earn Most Efficient status.
Does Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door qualify for the ENERGY STAR Northern Zone?
While Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door misses the <= 0.22 prescriptive mark (floor U 0.25), 23 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.
What conductive BTU/hr difference separates Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door for a residential project?
Skip Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door options exceeding U 0.22.
Can you install Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 58 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door, while total line SHGC reaches 0.37 in colder packages.
Does Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door carry EPA Most Efficient certification across its lineup?
No. Zero of the 63 configurations in Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
Can homeowners claim Form 5695 credits on Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door in 2026?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Anlin Industries upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do you cross-check NFRC ANL and product line ANL-A-1 on delivery?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code ANL and product line ANL-A-1, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Anlin Industries Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)