Skip to main content
Door · Vinyl Frame NFRC KKM · Product Line KKM-N-276

Kolbe and Kolbe Millwork Co., Inc — Forgent Complementary Multislide Door · Sliding Patio Door

Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door is a Sliding Patio Door assembly with a Vinyl frame that reaches a minimum U-Factor of 0.25 across 90 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #216 of 268 in Door, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.39.

Min U-Factor
0.25
SHGC Range
0.10-0.39
Certified Options
90
Category Standing
#216 of 268

How does Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door compare thermally against Door peers?

Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Forgent Complementary Multislide DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Forgent Complementary Multislide Door (U 0.25).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.25100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Forgent Complementary Multislide Door Cohort StandingMin U-Factor 0.25 stands at rank #216 of 268, outperforming 13.4% of peers.Min U-Factor 0.25Rank #216 of 268 (13.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Forgent Complementary Multislide Door reaches 0.25 on its lowest-conductivity package — #907 of 1,009 in Vinyl, tied with 49 others at 0.25, more insulating than 5.3% of Vinyl lines (+0.06 vs Vinyl peers). Pairing NFRC ID KKM across multi-pane fills shifts U-Factor from 0.28 down toward 0.25.

Climate coverage for Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 39 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2026-09-25 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 90 certified glazing combinations for Forgent Complementary Multislide Door (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 39 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 39 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 79 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 79 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door appear below.

Where does Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door stand thermally among ENERGY STAR Door lines?

EPA ENERGY STAR v7.0 records 90 configurations for Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Does Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern approval ends at U <= 0.22, above Forgent Complementary Multislide Door's 0.25 minimum. However, 39 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

What BTU/hr heat transfer results from Forgent Complementary Multislide Door's 0.25 minimum U-Factor?

Using NFRC KKM U-Factor 0.25, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

Who should NOT choose Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Forgent Complementary Multislide Door options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 79 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door, while total line SHGC reaches 0.39 in colder packages.

Which package tier in Forgent Complementary Multislide Door holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 90 Forgent Complementary Multislide Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Can homeowners claim Form 5695 credits on Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on Forgent Complementary Multislide Door?

Confirm both the paper NFRC label and permanent corner glass etch match line KKM-N-276 and NFRC ID KKM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Forgent Complementary Multislide Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros