Skip to main content
Window · Vinyl Frame NFRC SLL · Product Line SLL-A-89 ENERGY STAR Most Efficient Eligible

Soft-Lite, LLC — CPWL Casement Picture Window Low Profile · Picture Window

With a minimum U-Factor of 0.13—-0.07 compared against the 0.20 Window median—Soft-Lite, LLC CPWL Casement Picture Window Low Profile spans 925 tested options across Northern, North-Central, South-Central, Southern up to 0.27 U-Factor. Carrying NFRC CPD code SLL, the Vinyl assembly includes 374 ENERGY STAR Most Efficient packages (40.4% of line) and offers SHGC packages between 0.14 and 0.42.

Min U-Factor
0.13
SHGC Range
0.14-0.42
Certified Options
925
Category Standing
#36 of 1,352

How does Soft-Lite, LLC CPWL Casement Picture Window Low Profile compare thermally against Window peers?

Soft-Lite, LLC CPWL Casement Picture Window Low Profile achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. CPWL Casement Picture Window Low ProfileHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing CPWL Casement Picture Window Low Profile (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

CPWL Casement Picture Window Low Profile Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 13 certified Soft-Lite, LLC series, this Picture Window offers a 0.14 U-Factor adjustment span between 0.27 entry options and 0.13 top-performing glazing. Category standing is #36/1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%).

Mapping NFRC SHGC values (0.14 to 0.42) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 374 configurations meet ENERGY STAR Most Efficient criteria while 468 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 78.0 BTU/hr (-40.9% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-01-17.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 925 certified glazing combinations for CPWL Casement Picture Window Low Profile (NFRC SLL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 468 packages (240 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 775 packages (320 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 530 packages (164 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 530 packages (218 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Harvey Industries, Inc. — Axio Direct Set Fixed Window Vinyl 0.13 0.17 725
ProVia LLC — New Aspect/Endure Picture Window Vinyl 0.13 0.14 404
ProVia LLC — Vinyl Casement Picture Window Vinyl 0.13 0.06 365
Advanced Window Corp. — EU 76 Septem Fixed Vinyl 0.13 0.15 300
North Star Manufacturing (London) Ltd. — 1071 Fixed Vinyl 0.13 0.17 205

What other certified series does Soft-Lite, LLC produce?

Compare other active Soft-Lite, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Soft-Lite, LLC CPWL Casement Picture Window Low Profile appear below.

Where does Soft-Lite, LLC CPWL Casement Picture Window Low Profile stand thermally among ENERGY STAR Window lines?

Testing puts Soft-Lite, LLC CPWL Casement Picture Window Low Profile at rank #36 of 1,352 Window entries with U 0.13 to 0.27 across 925 configurations. Solar heat gain ranges between 0.14 and 0.42 across Northern, North-Central, South-Central, Southern.

Is CPWL Casement Picture Window Low Profile approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 468 CPWL Casement Picture Window Low Profile packages (U floor 0.13, SHGC >= 0.17). Because the complete series stretches up to U 0.27, specify the cold-climate glass code explicitly.

How do you calculate winter heat conduction for Soft-Lite, LLC CPWL Casement Picture Window Low Profile?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.13 U-Factor yields 78.0 BTU/hr conductive transfer (-40.9% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Soft-Lite, LLC CPWL Casement Picture Window Low Profile for a residential project?

Do not specify CPWL Casement Picture Window Low Profile without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on CPWL Casement Picture Window Low Profile options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does CPWL Casement Picture Window Low Profile meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 530 Southern-certified options inside Soft-Lite, LLC CPWL Casement Picture Window Low Profile satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in CPWL Casement Picture Window Low Profile holds Most Efficient recognition?

Only 374 options out of 925 (40.4%) meet tighter Most Efficient U-Factor and SHGC thresholds in Soft-Lite, LLC CPWL Casement Picture Window Low Profile, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 CPWL Casement Picture Window Low Profile window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current CPWL Casement Picture Window Low Profile retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify CPWL Casement Picture Window Low Profile glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.13-0.27, SHGC 0.14-0.42) against permit drawings for line SLL-A-89. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Soft-Lite, LLC CPWL Casement Picture Window Low Profile come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros