Soft-Lite, LLC — Pro DH11 Double Hung · Double Hung
Soft-Lite, LLC Pro DH11 Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.22 across 324 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.15 to 0.28.
- Min U-Factor
- 0.22
- SHGC Range
- 0.15-0.28
- Certified Options
- 324
- Category Standing
- #831 of 1,352
How does Soft-Lite, LLC Pro DH11 Double Hung compare thermally against Window peers?
Soft-Lite, LLC Pro DH11 Double Hung achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across Pro DH11 Double Hung spans 324 NFRC test records (SLL), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 27 configurations meet ENERGY STAR Most Efficient criteria while 45 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2025-04-22 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 324 certified glazing combinations for Pro DH11 Double Hung (NFRC SLL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 45 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 212 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 215 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 242 packages (27 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Vinylmax LLC — SH46 Picture Window | Vinyl | 0.22 | 0.20 | 335 |
| ESWindows LLC — ES-V150 Picture Window | Vinyl | 0.22 | 0.15 | 338 |
| WeatherBarr Windows and Doors — 9520 Single Hung | Vinyl | 0.22 | 0.17 | 276 |
| WeatherBarr Windows and Doors — 9520 XO Slider | Vinyl | 0.22 | 0.17 | 276 |
| Associated Materials, Inc. — 0704 Picture Window | Vinyl | 0.22 | 0.11 | 264 |
What other certified series does Soft-Lite, LLC produce?
Compare other active Soft-Lite, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
CPWL Casement Picture Window Low Profile
U-Factor 0.13–0.27 · 925 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Soft-Lite, LLC Pro DH11 Double Hung appear below.
Where does Soft-Lite, LLC Pro DH11 Double Hung stand thermally among ENERGY STAR Window lines?
Across 324 tested NFRC glazing configurations, Soft-Lite, LLC Pro DH11 Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.22 minimum U-Factor and 0.15-0.28 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.
Which glazing options in Soft-Lite, LLC Pro DH11 Double Hung meet Northern climate limits?
Prescriptive Northern compliance covers 45 Pro DH11 Double Hung packages (U floor 0.22, SHGC >= 0.17). Because the complete series stretches up to U 0.29, specify the cold-climate glass code explicitly.
How do you calculate winter heat conduction for Soft-Lite, LLC Pro DH11 Double Hung?
Using NFRC SLL U-Factor 0.22, a 15 sq ft Double-Hung (VSDH) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).
When should a buyer skip Soft-Lite, LLC Pro DH11 Double Hung and compare alternatives?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pro DH11 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
What Southern ENERGY STAR v7.0 options exist in Pro DH11 Double Hung?
Yes, Pro DH11 Double Hung holds 242 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.
Are all 324 Pro DH11 Double Hung configurations ENERGY STAR Most Efficient?
EPA lists 27 Most Efficient options (8.3% share) inside Soft-Lite, LLC Pro DH11 Double Hung, out of 324 total Version 7.0 entries.
What federal compliance checks govern 2026 Pro DH11 Double Hung window swaps?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Pro DH11 Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How do you cross-check NFRC SLL and product line SLL-A-64 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line SLL-A-64 and NFRC ID SLL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Soft-Lite, LLC Pro DH11 Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)