With a minimum U-Factor of 0.27—+0.07 compared against the 0.20 Window median—Walsh Building Products #4200 Single Slider spans 8 tested options across South-Central, Southern up to 0.30 U-Factor. Carrying NFRC CPD code WAL, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.20 and 0.22.

Min U-Factor
0.27
SHGC Range
0.20-0.22
Certified Options
8
Category Standing
#1,292 of 1,352

How does Walsh Building Products #4200 Single Slider compare thermally against Window peers?

Walsh Building Products #4200 Single Slider achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. #4200 Single SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing #4200 Single Slider (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

#4200 Single Slider Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across #4200 Single Slider spans 8 NFRC test records (WAL), ranking #1,292 of 1,352 Window families (tied with 27 others at 0.27, more insulating than 2.4% of Window lines). Its 0.27 thermal floor compares at +0.08 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.20 to 0.22) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.20 lowers cooling load.

Data provenance links certification 2023-11-09 and FENSTAR license 2018-07-12 inside EPA Version 7.0 tables. Heat transfer computes to 162.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8 certified glazing combinations for #4200 Single Slider (NFRC WAL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 4 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 8 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Duke Vinyl Windows — Marquis Picture Window Vinyl 0.27 0.17 12
Duke Vinyl Windows — Marquis Casement Vinyl 0.27 0.14 15
Vytex Corporation — Georgetown Double Hung Vinyl 0.27 0.19 16
Vytex Corporation — Georgetown Horizontal Slider Vinyl 0.27 0.18 16
Silver Line Building Products — 2130 IMPACT Fixed Window Vinyl 0.27 0.19 20

What other certified series does Walsh Building Products produce?

Compare other active Walsh Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Walsh Building Products #4200 Single Slider appear below.

What U-Factor and SHGC range does Walsh Building Products #4200 Single Slider achieve?

Built with Vinyl framing in Horizontal Slider (HSOX) style, Walsh Building Products #4200 Single Slider offers 8 Version 7.0 configurations from U 0.27 up to 0.30, posting +0.07 against the Window median of 0.20 with 0 Most Efficient picks.

Does Walsh Building Products #4200 Single Slider qualify for the ENERGY STAR Northern Zone?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.27). Focus on South-Central, Southern glazing applications where SHGC 0.20-0.22 manages cooling loads.

What conductive BTU/hr difference separates #4200 Single Slider from the 0.22 Northern rule?

Using NFRC WAL U-Factor 0.27, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 162.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+30.0 BTU/hr margin).

Which situations make #4200 Single Slider the wrong window or door choice?

Skip #4200 Single Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on #4200 Single Slider options exceeding U 0.22.

Does #4200 Single Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 8 Southern-certified options inside Walsh Building Products #4200 Single Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.22 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does #4200 Single Slider carry EPA Most Efficient certification across its lineup?

All 8 #4200 Single Slider listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 #4200 Single Slider installations qualify for IRS Section 25C tax credits?

Any #4200 Single Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on #4200 Single Slider?

Confirm both the paper NFRC label and permanent corner glass etch match line WAL-K-30 and NFRC ID WAL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Walsh Building Products #4200 Single Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros