Walsh Building Products — #5400 Double Hung · Double Hung

Positioning #1,292/1,352 in certified Window, Walsh Building Products #5400 Double Hung pairs Vinyl frame construction with 8 glazing options rated between 0.20 and 0.22 SHGC across South-Central, Southern. Across 10 certified Walsh Building Products product families, its thermal resistance spans 0.27 to 0.30 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.27
SHGC Range
0.20-0.22
Certified Options
8
Category Standing
#1,292 of 1,352

How does Walsh Building Products #5400 Double Hung compare thermally against Window peers?

Walsh Building Products #5400 Double Hung achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. #5400 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing #5400 Double Hung (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

#5400 Double Hung Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Walsh Building Products #5400 Double Hung standing at #1,292 of 1,352 certified Window product series, tied with 27 others at 0.27, more insulating than 2.4% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.08 before selecting Low-E tiers.

Regional qualification covers South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.20 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-07-12 and cert timestamp 2023-10-09.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8 certified glazing combinations for #5400 Double Hung (NFRC WAL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 4 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 8 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Duke Vinyl Windows — Marquis Picture Window Vinyl 0.27 0.17 12
Duke Vinyl Windows — Marquis Casement Vinyl 0.27 0.14 15
Vytex Corporation — Georgetown Double Hung Vinyl 0.27 0.19 16
Vytex Corporation — Georgetown Horizontal Slider Vinyl 0.27 0.18 16
Silver Line Building Products — 2130 IMPACT Fixed Window Vinyl 0.27 0.19 20

What other certified series does Walsh Building Products produce?

Compare other active Walsh Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Walsh Building Products #5400 Double Hung appear below.

What thermal performance numbers separate Walsh Building Products #5400 Double Hung from peers?

Testing puts Walsh Building Products #5400 Double Hung at rank #1,292 of 1,352 Window entries with U 0.27 to 0.30 across 8 configurations. Solar heat gain ranges between 0.20 and 0.22 across South-Central, Southern.

Is #5400 Double Hung approved for Northern Zone heating climates?

Northern Zone certification is absent for #5400 Double Hung (0 qualifying options, min U 0.27). Install this Double-Hung (VSDH) product only within South-Central, Southern regions where lower SHGC caps apply.

How do you calculate winter heat conduction for Walsh Building Products #5400 Double Hung?

At U 0.27, a standard 3x5 ft (15 sq ft) #5400 Double Hung opening transfers 162.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +30.0 BTU/hr difference.

What are the practical limitations of specifying #5400 Double Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on #5400 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in #5400 Double Hung?

Warm-climate homeowners have 8 Southern-approved options within #5400 Double Hung spanning SHGC down to 0.20. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside #5400 Double Hung qualifies as Most Efficient?

#5400 Double Hung holds zero Most Efficient entries across its 8 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect #5400 Double Hung?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 #5400 Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify #5400 Double Hung after sticker removal?

Verify NFRC ID WAL and series WAL-K-29 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Walsh Building Products #5400 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros