Skip to main content
Door · Wood Frame NFRC WEA · Product Line WEA-N-296

Weather Shield Mfg., Inc. — 6510/6610 Swing Door · Swinging Entry Door (Single)

Weather Shield Mfg., Inc. engineered the 6510/6610 Swing Door Swinging Entry Door, Single line for Northern, North-Central, South-Central, Southern, certifying 207 glass-spacer combinations from 0.26 to 0.28 U-Factor and 0.11 to 0.23 SHGC. Relative to other Wood models tracked under NFRC WEA, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.11-0.23
Certified Options
207
Category Standing
#233 of 268

How does Weather Shield Mfg., Inc. 6510/6610 Swing Door compare thermally against Door peers?

Weather Shield Mfg., Inc. 6510/6610 Swing Door achieves a 0.26 thermal floor across Door lines, placing #233 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 6510/6610 Swing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 6510/6610 Swing Door (U 0.26).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.26100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

6510/6610 Swing Door Cohort StandingMin U-Factor 0.26 stands at rank #233 of 268, outperforming 7.5% of peers.Min U-Factor 0.26Rank #233 of 268 (7.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), 6510/6610 Swing Door reaches 0.26 on its lowest-conductivity package — #352 of 408 in Wood, tied with 24 others at 0.26, more insulating than 7.8% of Wood lines (+0.05 vs Wood peers). Pairing NFRC ID WEA across multi-pane fills shifts U-Factor from 0.28 down toward 0.26.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 38 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2025-04-24. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.26 conducts 156.0 BTU/hr (+24.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 207 certified glazing combinations for 6510/6610 Swing Door (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 38 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 38 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 207 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 207 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 6510/6610 Swing Door appear below.

Where does Weather Shield Mfg., Inc. 6510/6610 Swing Door stand thermally among ENERGY STAR Door lines?

Across 207 tested NFRC glazing configurations, Weather Shield Mfg., Inc. 6510/6610 Swing Door with Wood framing and Entry Door Single-Lite (EDSL) style reaches a 0.26 minimum U-Factor and 0.11-0.23 SHGC band. It places #233 among 268 Door series—more insulating than 7.5%.

Does Weather Shield Mfg., Inc. 6510/6610 Swing Door qualify for the ENERGY STAR Northern Zone?

Because 6510/6610 Swing Door starts at 0.26 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 38 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

What conductive BTU/hr difference separates 6510/6610 Swing Door from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 6510/6610 Swing Door at U 0.26 conducts 156.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Weather Shield Mfg., Inc. 6510/6610 Swing Door and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 6510/6610 Swing Door options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

How many 6510/6610 Swing Door glazing packages pass Southern solar-heat rules?

Yes, 6510/6610 Swing Door holds 207 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

Are all 207 6510/6610 Swing Door configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 207 6510/6610 Swing Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 6510/6610 Swing Door window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 6510/6610 Swing Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 6510/6610 Swing Door after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line WEA-N-296 and NFRC ID WEA before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 6510/6610 Swing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros