Andersen Corporation — E-Series Hinged Outswing Patio Door · Swinging Entry Door (Double)

Across 111 Andersen Corporation certified families, E-Series Hinged Outswing Patio Door supplies 234 Swinging Entry Door, Double configurations starting at 0.26 U-Factor and 0.10 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.36 SHGC. Its thermal floor ranks #233 of 268 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.10-0.36
Certified Options
234
Category Standing
#233 of 268

How does Andersen Corporation E-Series Hinged Outswing Patio Door compare thermally against Door peers?

Andersen Corporation E-Series Hinged Outswing Patio Door achieves a 0.26 thermal floor across Door lines, placing #233 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. E-Series Hinged Outswing Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing E-Series Hinged Outswing Patio Door (U 0.26).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.26100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

E-Series Hinged Outswing Patio Door Cohort StandingMin U-Factor 0.26 stands at rank #233 of 268, outperforming 7.5% of peers.Min U-Factor 0.26Rank #233 of 268 (7.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across E-Series Hinged Outswing Patio Door spans 234 NFRC test records (AND), ranking #233 of 268 Door families (tied with 15 others at 0.26, more insulating than 7.5% of Door lines). Its 0.26 thermal floor compares at +0.05 against the Wood median (0.21).

Climate coverage for Andersen Corporation E-Series Hinged Outswing Patio Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 48 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors AND to 2024-03-07 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 156.0 BTU/hr conductive loss (+18.2% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 234 certified glazing combinations for E-Series Hinged Outswing Patio Door (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 48 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 48 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 220 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 220 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Hinged Outswing Patio Door appear below.

What thermal performance numbers separate Andersen Corporation E-Series Hinged Outswing Patio Door from peers?

Testing puts Andersen Corporation E-Series Hinged Outswing Patio Door at rank #233 of 268 Door entries with U 0.26 to 0.28 across 234 configurations. Solar heat gain ranges between 0.10 and 0.36 across Northern, North-Central, South-Central, Southern.

Does Andersen Corporation E-Series Hinged Outswing Patio Door qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern approval ends at U <= 0.22, above E-Series Hinged Outswing Patio Door's 0.26 minimum. However, 48 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How does a 3x5 ft E-Series Hinged Outswing Patio Door window perform under a 40 deg F temperature drop?

At U 0.26, a standard 3x5 ft (15 sq ft) E-Series Hinged Outswing Patio Door opening transfers 156.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +24.0 BTU/hr difference.

What are the practical limitations of specifying E-Series Hinged Outswing Patio Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Hinged Outswing Patio Door options exceeding U 0.22. Additionally, do not order Hinged Patio French Door (DDFR) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is E-Series Hinged Outswing Patio Door suitable for sunbelt cooling-dominated homes?

Yes, E-Series Hinged Outswing Patio Door holds 220 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.

How many Andersen Corporation E-Series Hinged Outswing Patio Door variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 234 E-Series Hinged Outswing Patio Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 E-Series Hinged Outswing Patio Door window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on E-Series Hinged Outswing Patio Door?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-168 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Hinged Outswing Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros