Skip to main content
Window · Aluminum Frame NFRC WCI · Product Line WCI-K-4

Winchester Industries — HDR-Bristol/Oxford Casement · Casement Windows

With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Winchester Industries HDR-Bristol/Oxford Casement spans 10 tested options across North-Central, South-Central, Southern up to 0.30 U-Factor. Carrying NFRC CPD code WCI, the Aluminum assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.15 and 0.22.

Min U-Factor
0.25
SHGC Range
0.15-0.22
Certified Options
10
Category Standing
#1,174 of 1,352

How does Winchester Industries HDR-Bristol/Oxford Casement compare thermally against Window peers?

Winchester Industries HDR-Bristol/Oxford Casement achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. HDR-Bristol/Oxford CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing HDR-Bristol/Oxford Casement (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

HDR-Bristol/Oxford Casement Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Winchester Industries HDR-Bristol/Oxford Casement at rank #1,174 of 1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.15-0.22 band.

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2023-12-04. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 10 certified glazing combinations for HDR-Bristol/Oxford Casement (NFRC WCI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 1 package (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 6 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 10 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Winchester Industries produce?

Compare other active Winchester Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Winchester Industries HDR-Bristol/Oxford Casement appear below.

What U-Factor and SHGC range does Winchester Industries HDR-Bristol/Oxford Casement achieve?

EPA ENERGY STAR v7.0 records 10 configurations for Winchester Industries HDR-Bristol/Oxford Casement covering North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Which glazing options in Winchester Industries HDR-Bristol/Oxford Casement meet Northern climate limits?

No. Because HDR-Bristol/Oxford Casement reaches only 0.25 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Aluminum line strictly across North-Central, South-Central, Southern cooling or mixed markets.

How do you calculate winter heat conduction for Winchester Industries HDR-Bristol/Oxford Casement?

At U 0.25, a standard 3x5 ft (15 sq ft) HDR-Bristol/Oxford Casement opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

What homeowner profiles are a poor match for Winchester Industries HDR-Bristol/Oxford Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on HDR-Bristol/Oxford Casement options exceeding U 0.22. Verify whether your municipal code restricts Aluminum frames in wildfire or historic zones.

Is HDR-Bristol/Oxford Casement suitable for sunbelt cooling-dominated homes?

Across North-Central, South-Central, Southern, 10 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Winchester Industries HDR-Bristol/Oxford Casement, while total line SHGC reaches 0.22 in colder packages.

How many Winchester Industries HDR-Bristol/Oxford Casement variants earn ENERGY STAR Most Efficient?

All 10 HDR-Bristol/Oxford Casement listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 HDR-Bristol/Oxford Casement installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 HDR-Bristol/Oxford Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify HDR-Bristol/Oxford Casement after sticker removal?

Match the NFRC thermal sticker for code WCI and line WCI-K-4 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Winchester Industries HDR-Bristol/Oxford Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros