QUANTAPANEL — 605-DH Architectural Low-e Storm Window ENERGY STAR Storm Window Specs
Benchmarking QUANTAPANEL 605-DH Architectural Low-e Storm Window across EPA's 30-model qaxz-ikcb registry places this Vertical Slider/Single-Double Hung Aluminum unit at 0.16 emissivity (0.01 lower emissivity than the 0.17 median), 0.74 solar transmission, and 0.40 cfm/ft2 air infiltration (0.70 cfm/ft2 tighter than the 1.10 median). Mounting Low-E Two-Track storm overlays at ~$188 per opening cuts single-pane heat loss by ~10% annually without altering historic window geometry.
- Low-E Emissivity
- 0.16 (<= 0.22)
- Solar Transmittance
- 0.74
- AERC Air Leakage
- 0.40 cfm/ft2
- Target Zone
- Northern
What optical and air-leakage specifications define QUANTAPANEL 605-DH Architectural Low-e Storm Window?
Inspect certified Low-E emissivity (0.16), solar heat transmittance (0.74), and AERC 1.2 air sealing for QUANTAPANEL 605-DH Architectural Low-e Storm Window in the table below.
| Storm Window Metric | Certified Value | EPA Benchmark / Engineering Context |
|---|---|---|
| Brand & Partner | QUANTAPANEL | Partner: QUANTA Technologies, Inc. |
| Model Number / Type | 605-DH Architectural Low-e Storm Window | Interior Storm Window |
| Emissivity Rating | 0.16 | EPA Low-E threshold <= 0.22 |
| Solar Transmittance | 0.74 | Zone-matched solar gain control |
| AERC 1.2 Air Leakage | 0.40 cfm/ft2 | Reduces single-pane sash drafts |
| Tracks & Glazing | Two-Track · 1 | Aluminum · Limited, 20 years |
Certified at 0.16 emissivity (below EPA's 0.22 cap; 0.01 lower emissivity than the 0.17 median), 605-DH Architectural Low-e Storm Window delivers steady convective and radiative insulation over intact historic wood sashes.
A 0.74 solar transmittance figure preserves bright daylighting and passive winter heat gain over Aluminum storm tracks in Northern installations.
At 0.40 cfm/ft2 air leakage (0.70 cfm/ft2 tighter than the 1.10 median), QUANTAPANEL 605-DH Architectural Low-e Storm Window cuts convective air wash along older single-pane glass without caulking sashes shut.
Alternative Comparison: Shoppers weighing 605-DH Architectural Low-e Storm Window (0.16 emissivity, 0.40 cfm/ft2) against Chosen Fixed Slip Low-e (0.16 / 1.50) and QUANTAPANEL 502-PW Architectural Low-e Storm Window N (0.16 / 1.10) see 0.00 solar transmittance variance.
Budget Payback Profile: EPA storm window field studies estimate ~10% annual HVAC savings (~$350/yr) when 0.16 Low-E units like 605-DH Architectural Low-e Storm Window cover leaky single-pane glass.
Sash Compatibility Check: QUANTAPANEL builds 605-DH Architectural Low-e Storm Window (605-DH Architectural Low-e Storm Window) in Aluminum with 1 glazing for Northern single-pane frames—confirm exterior blind-stop depth before ordering.
Which certified ENERGY STAR storm windows sit closest on emissivity and air sealing?
Review how 605-DH Architectural Low-e Storm Window compares directly against five similarly rated EPA storm tracks on Low-E surface coating and draft control.
| Peer Storm Window | Zone Target | Emissivity | Solar Trans. | Air Leakage |
|---|---|---|---|---|
| Chosen — Fixed Slip Low-e | Northern | 0.16 | 0.74 | 1.50 |
| QUANTAPANEL — 502-PW Architectural Low-e Storm Window N | Northern | 0.16 | 0.74 | 1.10 |
| QUANTAPANEL — 504-DH Architectural Low-e Storm Window N | Northern | 0.16 | 0.74 | 1.30 |
| QUANTAPANEL — 506-SL Architectural Low-e Storm Window N | Northern | 0.16 | 0.74 | 1.10 |
| QUANTAPANEL — 602-PW Architectural Low-e Storm Window | Northern | 0.16 | 0.74 | 0.10 |
Who should NOT install storm windows instead of full-frame units?
Verify blind-stop framing integrity and unblocked bottom sill drainage slots before mounting 605-DH Architectural Low-e Storm Window (Vertical Slider/Single-Double Hung) over historic single-pane windows.
Unsound window framing limits QUANTAPANEL storm overlays
Before hanging 605-DH Architectural Low-e Storm Window (Vertical Slider/Single-Double Hung), probe lower sills and blind stops for rot—covering damaged sashes hides ongoing decay instead of sealing an intact single-pane frame.
Preserving IRC R310 escape paths with 605-DH Architectural Low-e Storm Window
Ensure interior wood sashes stay tighter than the exterior 605-DH Architectural Low-e Storm Window storm track so warm indoor humidity does not condense on cold outer 1 glass.
What historic preservation, payback, and installation questions apply?
Direct buyer answers address annual HVAC payback, wood sash compatibility, coastal drainage, and installation limits for QUANTAPANEL 605-DH Architectural Low-e Storm Window below.
What utility payback does QUANTAPANEL 605-DH Architectural Low-e Storm Window deliver on older wood sashes?
Adding QUANTAPANEL 605-DH Architectural Low-e Storm Window (0.16 Low-E coating, 0.40 cfm/ft2 air leakage) at ~$188 per opening cuts single-pane conduction and draft losses by roughly 10% annually (~$350/yr), yielding an ~3-year payback.
What frame, track style, and warranty does 605-DH Architectural Low-e Storm Window carry?
QUANTAPANEL manufactures 605-DH Architectural Low-e Storm Window with Aluminum framing in an Vertical Slider/Single-Double Hung layout (Two-Track) glazed with 1 and backed by Limited, 20 years coverage.
Can 605-DH Architectural Low-e Storm Window be mounted on sleeping room windows under IRC code?
Exterior storm tracks like QUANTAPANEL 605-DH Architectural Low-e Storm Window mount outboard of existing wood stops, though operable sashes must slide cleanly open to preserve IRC Section R310 5.7 sq ft bedroom escape clearances.
Who should NOT buy QUANTAPANEL 605-DH Architectural Low-e Storm Window instead of full replacement?
Do not overlay 605-DH Architectural Low-e Storm Window (Aluminum) onto rotted perimeter frames, warped sashes that leak rainwater, or existing dual-pane units whose inner glass seals have already failed.
Which official federal and state sources back this page?
Every tested metric for QUANTAPANEL 605-DH Architectural Low-e Storm Window resolves directly to official EPA ENERGY STAR Storm Windows certification filings and IRC R310 guidelines.
- ENERGY STAR Certified Storm Windows Dataset (qaxz-ikcb) — U.S. EPA ENERGY STAR, 2026-11 (checked 2026-11-23)
- ENERGY STAR Windows, Doors, Skylights & Storm Windows Homeowner Savings Methodology — U.S. EPA / U.S. DOE ENERGY STAR, v7.0 (checked 2026-11-24)
- National Residential Efficiency Measures Database (REMDB) — Component Unit Cost Formulas — National Renewable Energy Laboratory (U.S. DOE), 2023 Cost Database (checked 2026-11-24)
- International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering) — International Code Council (ICC), 2021/2024 IRC (cite only) (checked 2026-11-23)