Skip to main content
Window · Vinyl Frame NFRC AWN · Product Line AWN-M-21

A Window, Inc. — V85 Horizontal Slider · Single Slider

Across 10 A Window, Inc. certified families, V85 Horizontal Slider supplies 429 Single Slider configurations starting at 0.26 U-Factor and 0.16 SHGC for South-Central, Southern, reaching up to 0.32 U-Factor and 0.22 SHGC. Its thermal floor ranks #1,256 of 1,352 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.16-0.22
Certified Options
429
Category Standing
#1,256 of 1,352

How does A Window, Inc. V85 Horizontal Slider compare thermally against Window peers?

A Window, Inc. V85 Horizontal Slider achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V85 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing V85 Horizontal Slider (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V85 Horizontal Slider Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows A Window, Inc. V85 Horizontal Slider standing at #1,256 of 1,352 certified Window product series, tied with 35 others at 0.26, more insulating than 4.5% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.07 before selecting Low-E tiers.

Climate coverage for A Window, Inc. V85 Horizontal Slider spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 156.0 BTU/hr (+18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2026-07-23.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 429 certified glazing combinations for V85 Horizontal Slider (NFRC AWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 102 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 429 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does A Window, Inc. produce?

Compare other active A Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to A Window, Inc. V85 Horizontal Slider appear below.

Where does A Window, Inc. V85 Horizontal Slider stand thermally among ENERGY STAR Window lines?

Across 429 tested NFRC glazing configurations, A Window, Inc. V85 Horizontal Slider with Vinyl framing and Horizontal Slider (HSOX) style reaches a 0.26 minimum U-Factor and 0.16-0.22 SHGC band. It places #1,256 among 1,352 Window series—more insulating than 4.5%.

Is V85 Horizontal Slider approved for Northern Zone heating climates?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.26). Focus on South-Central, Southern glazing applications where SHGC 0.16-0.22 manages cooling loads.

What conductive BTU/hr difference separates V85 Horizontal Slider from the 0.22 Northern rule?

At U 0.26, a standard 3x5 ft (15 sq ft) V85 Horizontal Slider opening transfers 156.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +24.0 BTU/hr difference.

What are the practical limitations of specifying V85 Horizontal Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on V85 Horizontal Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does V85 Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, V85 Horizontal Slider holds 429 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

What glazing share inside V85 Horizontal Slider qualifies as Most Efficient?

No. Zero of the 429 configurations in A Window, Inc. V85 Horizontal Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to V85 Horizontal Slider?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 A Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered A Window, Inc. V85 Horizontal Slider units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code AWN and product line AWN-M-21, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for A Window, Inc. V85 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)