Value Windows & Doors — IM-XO-2101 · Single Slider
Positioning #1,256/1,352 in certified Window, Value Windows & Doors IM-XO-2101 pairs Vinyl frame construction with 654 glazing options rated between 0.13 and 0.23 SHGC across South-Central, Southern. Across 16 certified Value Windows & Doors product families, its thermal resistance spans 0.26 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.
- Min U-Factor
- 0.26
- SHGC Range
- 0.13-0.23
- Certified Options
- 654
- Category Standing
- #1,256 of 1,352
How does Value Windows & Doors IM-XO-2101 compare thermally against Window peers?
Value Windows & Doors IM-XO-2101 achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), IM-XO-2101 reaches 0.26 on its lowest-conductivity package — #957 of 1,009 in Vinyl, tied with 14 others at 0.26, more insulating than 3.8% of Vinyl lines (+0.07 vs Vinyl peers). Pairing NFRC ID VWS across multi-pane fills shifts U-Factor from 0.32 down toward 0.26.
Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 156.0 BTU/hr (+18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-31 and cert timestamp 2026-11-02.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 654 certified glazing combinations for IM-XO-2101 (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 284 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 654 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| A Window, Inc. — V85 Horizontal Slider | Vinyl | 0.26 | 0.16 | 429 |
| A Window, Inc. — V85 Single Hung | Vinyl | 0.26 | 0.16 | 424 |
| Comfort View Products, LLC — Series 1500 Casement | Vinyl | 0.26 | 0.16 | 195 |
| Custom Window Systems, Inc. — 615/6150 Fixed | Vinyl | 0.26 | 0.14 | 144 |
| Pella Corporation — Pella Defender Series - Fixed | Vinyl | 0.26 | 0.14 | 144 |
What other certified series does Value Windows & Doors produce?
Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
EuroTek Tilt and Turn Window
U-Factor 0.17–0.27 · 219 certified options.
IM/GX/GS Sliding Patio Door
U-Factor 0.18–0.28 · 1,869 certified options.
EuroTek Outswing Door
U-Factor 0.19–0.27 · 64 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors IM-XO-2101 appear below.
What thermal performance numbers separate Value Windows & Doors IM-XO-2101 from peers?
Testing puts Value Windows & Doors IM-XO-2101 at rank #1,256 of 1,352 Window entries with U 0.26 to 0.32 across 654 configurations. Solar heat gain ranges between 0.13 and 0.23 across South-Central, Southern.
How does Value Windows & Doors IM-XO-2101 satisfy Version 7.0 Northern criteria?
Northern Zone certification is absent for IM-XO-2101 (0 qualifying options, min U 0.26). Install this Horizontal Slider (HSOX) product only within South-Central, Southern regions where lower SHGC caps apply.
What conductive BTU/hr difference separates IM-XO-2101 from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), IM-XO-2101 at U 0.26 conducts 156.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose Value Windows & Doors IM-XO-2101 for a residential project?
Skip IM-XO-2101 if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IM-XO-2101 options exceeding U 0.22.
Is IM-XO-2101 suitable for sunbelt cooling-dominated homes?
Yes. 654 Southern-certified options inside Value Windows & Doors IM-XO-2101 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.
What glazing share inside IM-XO-2101 qualifies as Most Efficient?
No. Zero of the 654 configurations in Value Windows & Doors IM-XO-2101 hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
What 2026 federal tax credit and Lead RRP rules apply to IM-XO-2101?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
What permanent glass etch marks verify IM-XO-2101 after sticker removal?
Verify NFRC ID VWS and series VWS-A-8 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors IM-XO-2101 come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)