Skip to main content
Window · Vinyl Frame NFRC VWS · Product Line VWS-A-8

Value Windows & Doors — IM-XO-2101 · Single Slider

Positioning #1,256/1,352 in certified Window, Value Windows & Doors IM-XO-2101 pairs Vinyl frame construction with 654 glazing options rated between 0.13 and 0.23 SHGC across South-Central, Southern. Across 16 certified Value Windows & Doors product families, its thermal resistance spans 0.26 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.26
SHGC Range
0.13-0.23
Certified Options
654
Category Standing
#1,256 of 1,352

How does Value Windows & Doors IM-XO-2101 compare thermally against Window peers?

Value Windows & Doors IM-XO-2101 achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IM-XO-2101Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing IM-XO-2101 (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IM-XO-2101 Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), IM-XO-2101 reaches 0.26 on its lowest-conductivity package — #957 of 1,009 in Vinyl, tied with 14 others at 0.26, more insulating than 3.8% of Vinyl lines (+0.07 vs Vinyl peers). Pairing NFRC ID VWS across multi-pane fills shifts U-Factor from 0.32 down toward 0.26.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 156.0 BTU/hr (+18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-31 and cert timestamp 2026-11-02.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 654 certified glazing combinations for IM-XO-2101 (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 284 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 654 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
A Window, Inc. — V85 Horizontal Slider Vinyl 0.26 0.16 429
A Window, Inc. — V85 Single Hung Vinyl 0.26 0.16 424
Comfort View Products, LLC — Series 1500 Casement Vinyl 0.26 0.16 195
Custom Window Systems, Inc. — 615/6150 Fixed Vinyl 0.26 0.14 144
Pella Corporation — Pella Defender Series - Fixed Vinyl 0.26 0.14 144

What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors IM-XO-2101 appear below.

What thermal performance numbers separate Value Windows & Doors IM-XO-2101 from peers?

Testing puts Value Windows & Doors IM-XO-2101 at rank #1,256 of 1,352 Window entries with U 0.26 to 0.32 across 654 configurations. Solar heat gain ranges between 0.13 and 0.23 across South-Central, Southern.

How does Value Windows & Doors IM-XO-2101 satisfy Version 7.0 Northern criteria?

Northern Zone certification is absent for IM-XO-2101 (0 qualifying options, min U 0.26). Install this Horizontal Slider (HSOX) product only within South-Central, Southern regions where lower SHGC caps apply.

What conductive BTU/hr difference separates IM-XO-2101 from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), IM-XO-2101 at U 0.26 conducts 156.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Value Windows & Doors IM-XO-2101 for a residential project?

Skip IM-XO-2101 if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IM-XO-2101 options exceeding U 0.22.

Is IM-XO-2101 suitable for sunbelt cooling-dominated homes?

Yes. 654 Southern-certified options inside Value Windows & Doors IM-XO-2101 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside IM-XO-2101 qualifies as Most Efficient?

No. Zero of the 654 configurations in Value Windows & Doors IM-XO-2101 hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to IM-XO-2101?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify IM-XO-2101 after sticker removal?

Verify NFRC ID VWS and series VWS-A-8 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors IM-XO-2101 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros