Skip to main content
Window · Vinyl Frame NFRC AWN · Product Line AWN-M-20

A Window, Inc. — V85 Single Hung · Single Hung

A Window, Inc. engineered the V85 Single Hung Single Hung line for South-Central, Southern, certifying 424 glass-spacer combinations from 0.26 to 0.32 U-Factor and 0.16 to 0.22 SHGC. Relative to other Vinyl models tracked under NFRC AWN, its minimum U-Factor is 0.07 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.16-0.22
Certified Options
424
Category Standing
#1,256 of 1,352

How does A Window, Inc. V85 Single Hung compare thermally against Window peers?

A Window, Inc. V85 Single Hung achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V85 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing V85 Single Hung (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V85 Single Hung Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), V85 Single Hung is 0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.26-0.32.

Mapping NFRC SHGC values (0.16 to 0.22) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Data provenance links certification 2026-04-02 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 156.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 424 certified glazing combinations for V85 Single Hung (NFRC AWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 102 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 424 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does A Window, Inc. produce?

Compare other active A Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to A Window, Inc. V85 Single Hung appear below.

How efficient is A Window, Inc. V85 Single Hung compared with peer Window models?

Built with Vinyl framing in Single-Hung (VSSH) style, A Window, Inc. V85 Single Hung offers 424 Version 7.0 configurations from U 0.26 up to 0.32, posting +0.06 against the Window median of 0.20 with 0 Most Efficient picks.

Is V85 Single Hung approved for Northern Zone heating climates?

Northern Zone certification is absent for V85 Single Hung (0 qualifying options, min U 0.26). Install this Single-Hung (VSSH) product only within South-Central, Southern regions where lower SHGC caps apply.

How do you calculate winter heat conduction for A Window, Inc. V85 Single Hung?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 156.0 BTU/hr on V85 Single Hung's lowest-U package (0.26), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip A Window, Inc. V85 Single Hung and compare alternatives?

Skip V85 Single Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on V85 Single Hung options exceeding U 0.22.

Does V85 Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Across South-Central, Southern, 424 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside A Window, Inc. V85 Single Hung, while total line SHGC reaches 0.22 in colder packages.

How many A Window, Inc. V85 Single Hung variants earn ENERGY STAR Most Efficient?

All 424 V85 Single Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to V85 Single Hung?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 A Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify V85 Single Hung glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line AWN-M-20 and NFRC ID AWN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for A Window, Inc. V85 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros