Skip to main content
Door · Wood Frame NFRC AND · Product Line AND-N-79

Andersen Corporation — 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill · Swinging Entry Door (Single)

Across 111 Andersen Corporation certified families, 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill supplies 23 Swinging Entry Door, Single configurations starting at 0.27 U-Factor and 0.12 SHGC for South-Central, Southern, reaching up to 0.28 U-Factor and 0.21 SHGC. Its thermal floor ranks #249 of 268 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.27
SHGC Range
0.12-0.21
Certified Options
23
Category Standing
#249 of 268

How does Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill compare thermally against Door peers?

Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill achieves a 0.27 thermal floor across Door lines, placing #249 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 200 Series Hinged Patio Door - Inswing; Low-Threshold SillHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill (U 0.27).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

200 Series Hinged Patio Door - Inswing; Low-Threshold Sill Cohort StandingMin U-Factor 0.27 stands at rank #249 of 268, outperforming 3.7% of peers.Min U-Factor 0.27Rank #249 of 268 (3.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill spans 23 NFRC test records (AND), ranking #249 of 268 Door families (tied with 9 others at 0.27, more insulating than 3.7% of Door lines). Its 0.27 thermal floor compares at +0.06 against the Wood median (0.21).

Climate coverage for Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-10-09.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 23 certified glazing combinations for 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 23 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 23 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill appear below.

Where does Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill stand thermally among ENERGY STAR Door lines?

Built with Wood framing in Entry Door Single-Lite (EDSL) style, Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill offers 23 Version 7.0 configurations from U 0.27 up to 0.28, posting +0.06 against the Door median of 0.21 with 0 Most Efficient picks.

How does Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill satisfy Version 7.0 Northern criteria?

No—with 0 Northern packages and a 0.27 thermal floor, Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill targets warmer South-Central, Southern climates instead of cold Northern installations.

How much winter heat loss does 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill conduct across a 15 sq ft opening?

At U 0.27, a standard 3x5 ft (15 sq ft) 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill opening transfers 162.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +30.0 BTU/hr difference.

Which situations make 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill the wrong window or door choice?

Skip 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill options exceeding U 0.22.

Does 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill meet Southern hot-climate SHGC caps (<= 0.23)?

Across South-Central, Southern, 23 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill, while total line SHGC reaches 0.21 in colder packages.

Does 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 23 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Can homeowners claim Form 5695 credits on Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-79 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)