Andersen Corporation — 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill · Swinging Entry Door (Single)
Across 111 Andersen Corporation certified families, 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill supplies 23 Swinging Entry Door, Single configurations starting at 0.27 U-Factor and 0.12 SHGC for South-Central, Southern, reaching up to 0.28 U-Factor and 0.21 SHGC. Its thermal floor ranks #249 of 268 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.27
- SHGC Range
- 0.12-0.21
- Certified Options
- 23
- Category Standing
- #249 of 268
How does Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill compare thermally against Door peers?
Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill achieves a 0.27 thermal floor across Door lines, placing #249 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill spans 23 NFRC test records (AND), ranking #249 of 268 Door families (tied with 9 others at 0.27, more insulating than 3.7% of Door lines). Its 0.27 thermal floor compares at +0.06 against the Wood median (0.21).
Climate coverage for Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-10-09.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 23 certified glazing combinations for 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 23 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 23 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Narrow Stile Outswing Patio Door | Wood | 0.27 | 0.13 | 35 |
| Windsor Windows and Doors — Pinnacle Clad Narrow Stile Outswing Stationary Panel | Wood | 0.27 | 0.13 | 35 |
| Weather Shield Mfg., Inc. — 8510/8610 Swing Door | Wood | 0.27 | 0.11 | 63 |
| Neuma Door — Folding Door | Composite | 0.27 | 0.09 | 15 |
| Weather Shield Mfg., Inc. — 4702 Sliding Patio Door | Aluminum | 0.27 | 0.17 | 8 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill appear below.
Where does Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill stand thermally among ENERGY STAR Door lines?
Built with Wood framing in Entry Door Single-Lite (EDSL) style, Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill offers 23 Version 7.0 configurations from U 0.27 up to 0.28, posting +0.06 against the Door median of 0.21 with 0 Most Efficient picks.
How does Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill satisfy Version 7.0 Northern criteria?
No—with 0 Northern packages and a 0.27 thermal floor, Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill targets warmer South-Central, Southern climates instead of cold Northern installations.
How much winter heat loss does 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill conduct across a 15 sq ft opening?
At U 0.27, a standard 3x5 ft (15 sq ft) 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill opening transfers 162.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +30.0 BTU/hr difference.
Which situations make 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill the wrong window or door choice?
Skip 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill options exceeding U 0.22.
Does 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill meet Southern hot-climate SHGC caps (<= 0.23)?
Across South-Central, Southern, 23 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill, while total line SHGC reaches 0.21 in colder packages.
Does 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill carry EPA Most Efficient certification across its lineup?
ENERGY STAR Most Efficient designation is absent across all 23 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
Can homeowners claim Form 5695 credits on Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill in 2026?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
What permanent glass etch marks verify 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill after sticker removal?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-79 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)