Window · Wood Frame NFRC AND · Product Line AND-N-27 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window · Picture Window

Positioning #477/1,352 in certified Window, Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window pairs Wood frame construction with 2,122 glazing options rated between 0.13 and 0.50 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.18 to 0.32 U-Factor and the line includes 176 ENERGY STAR Most Efficient packages (8.3% of line).

Min U-Factor
0.18
SHGC Range
0.13-0.50
Certified Options
2,122
Category Standing
#477 of 1,352

How does Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window compare thermally against Window peers?

Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Tilt-Wash Double-Hung Picture Full-Frame WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Tilt-Wash Double-Hung Picture Full-Frame Window Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.18-0.32.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 176 configurations meet ENERGY STAR Most Efficient criteria while 232 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2024-03-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,122 certified glazing combinations for 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 232 packages (62 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 640 packages (118 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 870 packages (70 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,794 packages (124 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Sierra Pacific Windows — H3 2.0 Direct Set Wood 0.18 0.11 1,846
Weather Shield Mfg., Inc. — 6121 Double Hung Transom Wood 0.18 0.11 2,658
JELD-WEN, inc. — Custom Clad Direct Set Geometric Wood 0.18 0.13 1,453
Marvin — Elevate Casement Wood 0.18 0.11 678
Marvin — Elevate Awning Wood 0.18 0.11 653

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window appear below.

What U-Factor and SHGC range does Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window achieve?

Across 2,122 tested NFRC glazing configurations, Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window with Wood framing and Fixed Window (FIXD) style reaches a 0.18 minimum U-Factor and 0.13-0.50 SHGC band. It places #477 among 1,352 Window series—top 41.6%.

Can homeowners install 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window in cold Northern ENERGY STAR counties?

Cold-climate buyers get 232 compliant Northern packages inside 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window?

Using NFRC AND U-Factor 0.18, a 15 sq ft Fixed Window (FIXD) assembly conducts 108.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-24.0 BTU/hr margin).

What are the practical limitations of specifying 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 1,794 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window, while total line SHGC reaches 0.50 in colder packages.

Does 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 176 of 2,122 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window glazing builds earn Most Efficient recognition (8.3%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window units match permits?

Match the NFRC thermal sticker for code AND and line AND-N-27 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros