Andersen Corporation — A-Series Frenchwood Gliding Patio Door · Sliding Patio Door
Across 111 Andersen Corporation certified families, A-Series Frenchwood Gliding Patio Door supplies 868 Sliding Patio Door configurations starting at 0.23 U-Factor and 0.11 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.36 SHGC. Its thermal floor ranks #162 of 268 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.23
- SHGC Range
- 0.11-0.36
- Certified Options
- 868
- Category Standing
- #162 of 268
How does Andersen Corporation A-Series Frenchwood Gliding Patio Door compare thermally against Door peers?
Andersen Corporation A-Series Frenchwood Gliding Patio Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across A-Series Frenchwood Gliding Patio Door spans 868 NFRC test records (AND), ranking #162 of 268 Door families (tied with 36 others at 0.23, more insulating than 26.1% of Door lines). Its 0.23 thermal floor compares at +0.02 against the Wood median (0.21).
Climate coverage for Andersen Corporation A-Series Frenchwood Gliding Patio Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 308 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Data provenance links certification 2024-03-07 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 868 certified glazing combinations for A-Series Frenchwood Gliding Patio Door (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 308 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 308 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 820 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 820 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| JELD-WEN, inc. — Siteline Clad Swinging Door | Wood | 0.23 | 0.11 | 971 |
| Weather Shield Mfg., Inc. — 8622 Premium / 8623 Contemporary Bi-Fold Door | Wood | 0.23 | 0.10 | 1,008 |
| Sierra Pacific Windows — Clad Outswing Door | Wood | 0.23 | 0.06 | 1,159 |
| JELD-WEN, inc. — Siteline Clad Wood Low Friction Gliding Door | Wood | 0.23 | 0.16 | 194 |
| JELD-WEN, inc. — Custom Clad HGD Outswing Door | Wood | 0.23 | 0.14 | 146 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Frenchwood Gliding Patio Door appear below.
Where does Andersen Corporation A-Series Frenchwood Gliding Patio Door stand thermally among ENERGY STAR Door lines?
Built with Wood framing in Sliding Glass Door (DDSG) style, Andersen Corporation A-Series Frenchwood Gliding Patio Door offers 868 Version 7.0 configurations from U 0.23 up to 0.28, posting +0.02 against the Door median of 0.21 with 0 Most Efficient picks.
Which glazing options in Andersen Corporation A-Series Frenchwood Gliding Patio Door meet Northern climate limits?
Northern qualification on A-Series Frenchwood Gliding Patio Door relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 308 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
How do you calculate winter heat conduction for Andersen Corporation A-Series Frenchwood Gliding Patio Door?
At U 0.23, a standard 3x5 ft (15 sq ft) A-Series Frenchwood Gliding Patio Door opening transfers 138.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +6.0 BTU/hr difference.
Who should NOT choose Andersen Corporation A-Series Frenchwood Gliding Patio Door for a residential project?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Frenchwood Gliding Patio Door options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.
How many A-Series Frenchwood Gliding Patio Door glazing packages pass Southern solar-heat rules?
Yes. 820 Southern-certified options inside Andersen Corporation A-Series Frenchwood Gliding Patio Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.36 SHGC on west-facing glass to avoid excess afternoon solar gain.
How many Andersen Corporation A-Series Frenchwood Gliding Patio Door variants earn ENERGY STAR Most Efficient?
Zero glazing builds inside A-Series Frenchwood Gliding Patio Door's 868 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
Do 2026 A-Series Frenchwood Gliding Patio Door installations qualify for IRS Section 25C tax credits?
Any A-Series Frenchwood Gliding Patio Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do you cross-check NFRC AND and product line AND-N-99 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-99 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Frenchwood Gliding Patio Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)