Skip to main content
Door · Wood Frame NFRC AND · Product Line AND-N-165

Andersen Corporation — E-Series Hinged Patio Door - Inswing · Swinging Entry Door (Double)

EPA ENERGY STAR Version 7.0 certifies 2,534 variants inside Andersen Corporation E-Series Hinged Patio Door - Inswing, combining Wood frame construction with U-Factors spanning 0.23 to 0.28 and SHGC 0.07 to 0.38. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Double family places #162 of 268 among 268 Door families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.23
SHGC Range
0.07-0.38
Certified Options
2,534
Category Standing
#162 of 268

How does Andersen Corporation E-Series Hinged Patio Door - Inswing compare thermally against Door peers?

Andersen Corporation E-Series Hinged Patio Door - Inswing achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. E-Series Hinged Patio Door - InswingHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing E-Series Hinged Patio Door - Inswing (U 0.23).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.23430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

E-Series Hinged Patio Door - Inswing Cohort StandingMin U-Factor 0.23 stands at rank #162 of 268, outperforming 26.1% of peers.Min U-Factor 0.23Rank #162 of 268 (26.1% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), E-Series Hinged Patio Door - Inswing reaches 0.23 on its lowest-conductivity package — #246 of 408 in Wood, tied with 33 others at 0.23, more insulating than 31.6% of Wood lines (+0.02 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.28 down toward 0.23.

Climate coverage for Andersen Corporation E-Series Hinged Patio Door - Inswing spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 451 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-04-11 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,534 certified glazing combinations for E-Series Hinged Patio Door - Inswing (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 451 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 451 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2,454 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2,454 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Hinged Patio Door - Inswing appear below.

How well does E-Series Hinged Patio Door - Inswing by Andersen Corporation insulate relative to Door benchmarks?

Testing puts Andersen Corporation E-Series Hinged Patio Door - Inswing at rank #162 of 268 Door entries with U 0.23 to 0.28 across 2,534 configurations. Solar heat gain ranges between 0.07 and 0.38 across Northern, North-Central, South-Central, Southern.

Can homeowners install E-Series Hinged Patio Door - Inswing in cold Northern ENERGY STAR counties?

Prescriptive Northern approval ends at U <= 0.22, above E-Series Hinged Patio Door - Inswing's 0.23 minimum. However, 451 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How does a 3x5 ft E-Series Hinged Patio Door - Inswing window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), E-Series Hinged Patio Door - Inswing at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Andersen Corporation E-Series Hinged Patio Door - Inswing and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Hinged Patio Door - Inswing options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Andersen Corporation E-Series Hinged Patio Door - Inswing in Southern or South-Central zones?

Yes, E-Series Hinged Patio Door - Inswing holds 2,454 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.

Are all 2,534 E-Series Hinged Patio Door - Inswing configurations ENERGY STAR Most Efficient?

All 2,534 E-Series Hinged Patio Door - Inswing listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Can homeowners claim Form 5695 credits on Andersen Corporation E-Series Hinged Patio Door - Inswing in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 E-Series Hinged Patio Door - Inswing installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on E-Series Hinged Patio Door - Inswing?

Match the NFRC thermal sticker for code AND and line AND-N-165 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Hinged Patio Door - Inswing come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros