Skip to main content
Window · Vinyl Frame NFRC BRW · Product Line BRW-A-10 ENERGY STAR Most Efficient Eligible

Burris Windows — TectView AC Picture · Picture Window

Burris Windows TectView AC Picture is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.22 across 110 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.23.

Min U-Factor
0.22
SHGC Range
0.12-0.23
Certified Options
110
Category Standing
#831 of 1,352

How does Burris Windows TectView AC Picture compare thermally against Window peers?

Burris Windows TectView AC Picture achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. TectView AC PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing TectView AC Picture (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

TectView AC Picture Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 3 certified Burris Windows series, this Picture Window offers a 0.10 U-Factor adjustment span between 0.32 entry options and 0.22 top-performing glazing. Category standing is #831/1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 5 configurations meet ENERGY STAR Most Efficient criteria while 5 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2018-10-03 and cert timestamp 2024-06-20.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 110 certified glazing combinations for TectView AC Picture (NFRC BRW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 5 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 33 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 78 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 110 packages (5 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Burris Windows produce?

Compare other active Burris Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Burris Windows TectView AC Picture appear below.

How well does TectView AC Picture by Burris Windows insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 110 configurations for Burris Windows TectView AC Picture covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.20 Window median. Only 5 options earn Most Efficient status.

Is TectView AC Picture approved for Northern Zone heating climates?

Yes, 5 packages satisfy Northern ENERGY STAR Version 7.0 rules in TectView AC Picture. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How does a 3x5 ft TectView AC Picture window perform under a 40 deg F temperature drop?

At U 0.22, a standard 3x5 ft (15 sq ft) TectView AC Picture opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

What homeowner profiles are a poor match for Burris Windows TectView AC Picture?

Do not specify TectView AC Picture without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on TectView AC Picture options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in TectView AC Picture?

Yes. 110 Southern-certified options inside Burris Windows TectView AC Picture satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does TectView AC Picture carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 5 of 110 TectView AC Picture glazing builds earn Most Efficient recognition (4.5%), while other variants sit on the standard Version 7.0 tier.

Do 2026 TectView AC Picture installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Burris Windows TectView AC Picture units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code BRW and product line BRW-A-10, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Burris Windows TectView AC Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros