Interstate Building Materials, Inc. — 145/5000/5100/5200 Direct Set Picture Window · Picture Window
EPA ENERGY STAR Version 7.0 certifies 130 variants inside Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window, combining Vinyl frame construction with U-Factors spanning 0.22 to 0.29 and SHGC 0.19 to 0.52. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #831 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.22
- SHGC Range
- 0.19-0.52
- Certified Options
- 130
- Category Standing
- #831 of 1,352
How does Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window compare thermally against Window peers?
Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 15 certified Interstate Building Materials, Inc. series, this Picture Window offers a 0.07 U-Factor adjustment span between 0.29 entry options and 0.22 top-performing glazing. Category standing is #831/1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines).
Climate coverage for Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 3 configurations meet ENERGY STAR Most Efficient criteria while 36 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors IBM to 2024-08-01 certification (FENSTAR issued 2018-09-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 130 certified glazing combinations for 145/5000/5100/5200 Direct Set Picture Window (NFRC IBM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 36 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 60 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 67 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 70 packages (3 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| NT Window, Inc. — E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window | Vinyl | 0.22 | 0.13 | 132 |
| Kasson and Keller — 300B Horizontal Slider | Vinyl | 0.22 | 0.22 | 144 |
| Kasson and Keller — 300C Horizontal Slider | Vinyl | 0.22 | 0.22 | 144 |
| Burris Windows — TectView AC Picture | Vinyl | 0.22 | 0.12 | 110 |
| Lindsay Windows — 183 Picture Window | Vinyl | 0.22 | 0.15 | 102 |
What other certified series does Interstate Building Materials, Inc. produce?
Compare other active Interstate Building Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
442/6802 Direct Set CS Picture Window
U-Factor 0.14–0.27 · 1,806 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window appear below.
What thermal performance numbers separate Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window from peers?
Across 130 tested NFRC glazing configurations, Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.19-0.52 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.
Is 145/5000/5100/5200 Direct Set Picture Window approved for Northern Zone heating climates?
Cold-climate buyers get 36 compliant Northern packages inside 145/5000/5100/5200 Direct Set Picture Window, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.29 options.
How do you calculate winter heat conduction for Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 145/5000/5100/5200 Direct Set Picture Window at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 145/5000/5100/5200 Direct Set Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Is 145/5000/5100/5200 Direct Set Picture Window suitable for sunbelt cooling-dominated homes?
Warm-climate homeowners have 70 Southern-approved options within 145/5000/5100/5200 Direct Set Picture Window spanning SHGC down to 0.19. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside 145/5000/5100/5200 Direct Set Picture Window qualifies as Most Efficient?
No. Exactly 3 of 130 configurations (2.3%) earn ENERGY STAR Most Efficient status in 145/5000/5100/5200 Direct Set Picture Window; the remaining standard v7.0 options pass base zone limits only.
Can homeowners claim Form 5695 credits on Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window in 2026?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
What permanent glass etch marks verify 145/5000/5100/5200 Direct Set Picture Window after sticker removal?
Match the NFRC thermal sticker for code IBM and line IBM-K-55 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Interstate Building Materials, Inc. 145/5000/5100/5200 Direct Set Picture Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)