Skip to main content
Window · Vinyl Frame NFRC KKI · Product Line KKI-K-62

Kasson and Keller — 300B Horizontal Slider · Double Slider

EPA ENERGY STAR Version 7.0 certifies 144 variants inside Kasson and Keller 300B Horizontal Slider, combining Vinyl frame construction with U-Factors spanning 0.22 to 0.26 and SHGC 0.22 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #831 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.22
SHGC Range
0.22-0.49
Certified Options
144
Category Standing
#831 of 1,352

How does Kasson and Keller 300B Horizontal Slider compare thermally against Window peers?

Kasson and Keller 300B Horizontal Slider achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 300B Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 300B Horizontal Slider (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

300B Horizontal Slider Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 300B Horizontal Slider reaches 0.22 on its lowest-conductivity package — #640 of 1,009 in Vinyl, tied with 75 others at 0.22, more insulating than 29.1% of Vinyl lines (+0.03 vs Vinyl peers). Pairing NFRC ID KKI across multi-pane fills shifts U-Factor from 0.26 down toward 0.22.

Regional qualification covers Northern, North-Central, South-Central, Southern. 78 combinations qualify in the Northern Zone alongside 32 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Data provenance links certification 2025-08-11 and FENSTAR license 2019-01-30 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 144 certified glazing combinations for 300B Horizontal Slider (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 78 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 77 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 32 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 32 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 300B Horizontal Slider appear below.

Where does Kasson and Keller 300B Horizontal Slider stand thermally among ENERGY STAR Window lines?

Kasson and Keller 300B Horizontal Slider spans 144 certified configurations with U-Factors between 0.22 and 0.26 and SHGC values from 0.22 to 0.49. Ranked #831 of 1,352 Window families, it carries 0 Most Efficient options.

Is 300B Horizontal Slider approved for Northern Zone heating climates?

Yes. 78 packages in Kasson and Keller 300B Horizontal Slider clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.26.

How does a 3x5 ft 300B Horizontal Slider window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 300B Horizontal Slider at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make 300B Horizontal Slider the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 300B Horizontal Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many 300B Horizontal Slider glazing packages pass Southern solar-heat rules?

Yes. 32 Southern-certified options inside Kasson and Keller 300B Horizontal Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside 300B Horizontal Slider qualifies as Most Efficient?

No. Zero of the 144 configurations in Kasson and Keller 300B Horizontal Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect 300B Horizontal Slider?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kasson and Keller upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Kasson and Keller 300B Horizontal Slider units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line KKI-K-62 and NFRC ID KKI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 300B Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros