Skip to main content
Window · Vinyl Frame NFRC NTW · Product Line NTW-A-15 ENERGY STAR Most Efficient Eligible

NT Window, Inc. — E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window · Picture Window

NT Window, Inc. engineered the E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 132 glass-spacer combinations from 0.22 to 0.30 U-Factor and 0.13 to 0.23 SHGC. Relative to other Vinyl models tracked under NFRC NTW, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.13-0.23
Certified Options
132
Category Standing
#831 of 1,352

How does NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window compare thermally against Window peers?

NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window spans 132 NFRC test records (NTW), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 3 configurations meet ENERGY STAR Most Efficient criteria while 1 combination satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-01-10 licensing and 2024-04-26 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 132 certified glazing combinations for E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 1 package (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 36 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 110 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 132 packages (3 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window appear below.

What U-Factor and SHGC range does NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window achieve?

Testing puts NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window at rank #831 of 1,352 Window entries with U 0.22 to 0.30 across 132 configurations. Solar heat gain ranges between 0.13 and 0.23 across Northern, North-Central, South-Central, Southern.

Is E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window approved for Northern Zone heating climates?

Yes, 1 package satisfy Northern ENERGY STAR Version 7.0 rules in E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window?

Using NFRC NTW U-Factor 0.22, a 15 sq ft Fixed Window (FIXD) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).

Who should NOT choose NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window for a residential project?

Do not specify E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 132 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window, while total line SHGC reaches 0.23 in colder packages.

Does E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window carry EPA Most Efficient certification across its lineup?

Only 3 options out of 132 (2.3%) meet tighter Most Efficient U-Factor and SHGC thresholds in NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window?

Match the NFRC thermal sticker for code NTW and line NTW-A-15 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros