NT Window, Inc. — E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window · Picture Window
NT Window, Inc. engineered the E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 132 glass-spacer combinations from 0.22 to 0.30 U-Factor and 0.13 to 0.23 SHGC. Relative to other Vinyl models tracked under NFRC NTW, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.22
- SHGC Range
- 0.13-0.23
- Certified Options
- 132
- Category Standing
- #831 of 1,352
How does NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window compare thermally against Window peers?
NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window spans 132 NFRC test records (NTW), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 3 configurations meet ENERGY STAR Most Efficient criteria while 1 combination satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-01-10 licensing and 2024-04-26 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 132 certified glazing combinations for E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 1 package (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 36 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 110 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 132 packages (3 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Interstate Building Materials, Inc. — 145/5000/5100/5200 Direct Set Picture Window | Vinyl | 0.22 | 0.19 | 130 |
| Kasson and Keller — 300B Horizontal Slider | Vinyl | 0.22 | 0.22 | 144 |
| Kasson and Keller — 300C Horizontal Slider | Vinyl | 0.22 | 0.22 | 144 |
| Burris Windows — TectView AC Picture | Vinyl | 0.22 | 0.12 | 110 |
| Lindsay Windows — 183 Picture Window | Vinyl | 0.22 | 0.15 | 102 |
What other certified series does NT Window, Inc. produce?
Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window appear below.
What U-Factor and SHGC range does NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window achieve?
Testing puts NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window at rank #831 of 1,352 Window entries with U 0.22 to 0.30 across 132 configurations. Solar heat gain ranges between 0.13 and 0.23 across Northern, North-Central, South-Central, Southern.
Is E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window approved for Northern Zone heating climates?
Yes, 1 package satisfy Northern ENERGY STAR Version 7.0 rules in E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How do you calculate winter heat conduction for NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window?
Using NFRC NTW U-Factor 0.22, a 15 sq ft Fixed Window (FIXD) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).
Who should NOT choose NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window for a residential project?
Do not specify E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
How many E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window glazing packages pass Southern solar-heat rules?
Across Northern, North-Central, South-Central, Southern, 132 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window, while total line SHGC reaches 0.23 in colder packages.
Does E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window carry EPA Most Efficient certification across its lineup?
Only 3 options out of 132 (2.3%) meet tighter Most Efficient U-Factor and SHGC thresholds in NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window, usually requiring triple-pane or upgraded Low-E coatings.
What federal compliance checks govern 2026 E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window window swaps?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window?
Match the NFRC thermal sticker for code NTW and line NTW-A-15 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)