Skip to main content
Door · Vinyl Frame NFRC DRU · Product Line DRU-K-13

DRUTEX S.A. — IGLO 5 Inswing Door · Swinging Entry Door (Single)

Positioning #75/268 in certified Door, DRUTEX S.A. IGLO 5 Inswing Door pairs Vinyl frame construction with 1,602 glazing options rated between 0.12 and 0.38 SHGC across Northern, North-Central, South-Central, Southern. Across 40 certified DRUTEX S.A. product families, its thermal resistance spans 0.18 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.18
SHGC Range
0.12-0.38
Certified Options
1,602
Category Standing
#75 of 268

How does DRUTEX S.A. IGLO 5 Inswing Door compare thermally against Door peers?

DRUTEX S.A. IGLO 5 Inswing Door achieves a 0.18 thermal floor across Door lines, placing #75 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. IGLO 5 Inswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing IGLO 5 Inswing Door (U 0.18).28<=0.15650.16-0.18This model: U 0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

IGLO 5 Inswing Door Cohort StandingMin U-Factor 0.18 stands at rank #75 of 268, outperforming 65.3% of peers.Min U-Factor 0.18Rank #75 of 268 (65.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 40 certified DRUTEX S.A. series, this Swinging Entry Door, Single offers a 0.10 U-Factor adjustment span between 0.28 entry options and 0.18 top-performing glazing. Category standing is #75/268 (tied with 18 others at 0.18, more insulating than 65.3% of Door lines, top 34.7%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 1,061 combinations qualify in the Northern Zone alongside 1,471 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.18 U-Factor yields 108.0 BTU/hr transfer (-24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2024-04-15 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,602 certified glazing combinations for IGLO 5 Inswing Door (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 1,061 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 1,061 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,471 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,471 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Value Windows & Doors — IM/GX/GS Sliding Patio Door Vinyl 0.18 0.07 1,869
Vinylmax LLC — PD3 Patio Door Vinyl 0.18 0.06 1,217
Neuma Door — Neuma Gliding Door Vinyl 0.18 0.03 185
Mathews Brothers Company — Sanford Hills Sliding Patio Door Vinyl 0.18 0.17 124
Lindsay Windows — Freedom Door Vinyl 0.18 0.16 82

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO 5 Inswing Door appear below.

How efficient is DRUTEX S.A. IGLO 5 Inswing Door compared with peer Door models?

Built with Vinyl framing in Entry Door Single-Lite (EDSL) style, DRUTEX S.A. IGLO 5 Inswing Door offers 1,602 Version 7.0 configurations from U 0.18 up to 0.28, posting -0.03 against the Door median of 0.21 with 0 Most Efficient picks.

Which glazing options in DRUTEX S.A. IGLO 5 Inswing Door meet Northern climate limits?

Yes. 1,061 packages in DRUTEX S.A. IGLO 5 Inswing Door clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

What BTU/hr heat transfer results from IGLO 5 Inswing Door's 0.18 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for DRUTEX S.A. IGLO 5 Inswing Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO 5 Inswing Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install DRUTEX S.A. IGLO 5 Inswing Door in Southern or South-Central zones?

Yes. 1,471 Southern-certified options inside DRUTEX S.A. IGLO 5 Inswing Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.38 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in IGLO 5 Inswing Door holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 1,602 IGLO 5 Inswing Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to IGLO 5 Inswing Door?

Any IGLO 5 Inswing Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC DRU and product line DRU-K-13 on delivery?

Verify NFRC ID DRU and series DRU-K-13 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO 5 Inswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros