Skip to main content
Door · Vinyl Frame NFRC VIM · Product Line VIM-M-10 ENERGY STAR Most Efficient Eligible

Vinylmax LLC — PD3 Patio Door · Sliding Patio Door

Vinylmax LLC PD3 Patio Door is a Sliding Patio Door assembly with a Vinyl frame that reaches a minimum U-Factor of 0.18 across 1,217 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #75 of 268 in Door, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.06 to 0.40.

Min U-Factor
0.18
SHGC Range
0.06-0.40
Certified Options
1,217
Category Standing
#75 of 268

How does Vinylmax LLC PD3 Patio Door compare thermally against Door peers?

Vinylmax LLC PD3 Patio Door achieves a 0.18 thermal floor across Door lines, placing #75 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. PD3 Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing PD3 Patio Door (U 0.18).28<=0.15650.16-0.18This model: U 0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

PD3 Patio Door Cohort StandingMin U-Factor 0.18 stands at rank #75 of 268, outperforming 65.3% of peers.Min U-Factor 0.18Rank #75 of 268 (65.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 12 certified Vinylmax LLC series, this Sliding Patio Door offers a 0.10 U-Factor adjustment span between 0.28 entry options and 0.18 top-performing glazing. Category standing is #75/268 (tied with 18 others at 0.18, more insulating than 65.3% of Door lines, top 34.7%).

Climate coverage for Vinylmax LLC PD3 Patio Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 195 configurations meet ENERGY STAR Most Efficient criteria while 990 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-21. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,217 certified glazing combinations for PD3 Patio Door (NFRC VIM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 990 packages (50 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 990 packages (91 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 766 packages (72 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 766 packages (176 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
DRUTEX S.A. — IGLO 5 Inswing Door Vinyl 0.18 0.12 1,602
Value Windows & Doors — IM/GX/GS Sliding Patio Door Vinyl 0.18 0.07 1,869
DRUTEX S.A. — IGLO 5 Classic Balcony Door Vinyl 0.18 0.14 540
Neuma Door — Neuma Gliding Door Vinyl 0.18 0.03 185
Mathews Brothers Company — Sanford Hills Sliding Patio Door Vinyl 0.18 0.17 124

What other certified series does Vinylmax LLC produce?

Compare other active Vinylmax LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinylmax LLC PD3 Patio Door appear below.

What thermal performance numbers separate Vinylmax LLC PD3 Patio Door from peers?

EPA ENERGY STAR v7.0 records 1,217 configurations for Vinylmax LLC PD3 Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.18 versus a 0.21 Door median. Only 195 options earn Most Efficient status.

Which glazing options in Vinylmax LLC PD3 Patio Door meet Northern climate limits?

Yes. 990 packages in Vinylmax LLC PD3 Patio Door clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

How do you calculate winter heat conduction for Vinylmax LLC PD3 Patio Door?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), PD3 Patio Door at U 0.18 conducts 108.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying PD3 Patio Door?

Do not specify PD3 Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on PD3 Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many PD3 Patio Door glazing packages pass Southern solar-heat rules?

Yes, PD3 Patio Door holds 766 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.06 SHGC in cooling climates.

Does PD3 Patio Door carry EPA Most Efficient certification across its lineup?

No. Exactly 195 of 1,217 configurations (16.0%) earn ENERGY STAR Most Efficient status in PD3 Patio Door; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect PD3 Patio Door?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 PD3 Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC VIM and product line VIM-M-10 on delivery?

Inspectors match the temporary NFRC sticker (U 0.18-0.28, SHGC 0.06-0.40) against permit drawings for line VIM-M-10. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinylmax LLC PD3 Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros