DRUTEX S.A. — IGLO EXT Single Swing Outward Opening Door (Full Lite Only) · Swinging Entry Door (Single)
EPA ENERGY STAR Version 7.0 certifies 35 variants inside DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only), combining Vinyl frame construction with U-Factors spanning 0.18 to 0.28 and SHGC 0.21 to 0.37. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Single family places #75 of 268 among 268 Door families and posts 0.01 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.18
- SHGC Range
- 0.21-0.37
- Certified Options
- 35
- Category Standing
- #75 of 268
How does DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) compare thermally against Door peers?
DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) achieves a 0.18 thermal floor across Door lines, placing #75 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Door assemblies nationwide (median U 0.21), IGLO EXT Single Swing Outward Opening Door (Full Lite Only) is 0.03 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.18-0.28.
Regional qualification covers Northern, North-Central, South-Central, Southern. 21 combinations qualify in the Northern Zone alongside 14 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2023-04-03 and cert timestamp 2024-10-09.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 35 certified glazing combinations for IGLO EXT Single Swing Outward Opening Door (Full Lite Only) (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 21 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 21 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 14 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 14 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Gilkey Window Company — S-7500 Patio Door | Vinyl | 0.18 | 0.16 | 16 |
| Kohltech International, Ltd. — Select Patio Door | Vinyl | 0.18 | 0.22 | 5 |
| Lindsay Windows — Freedom Door | Vinyl | 0.18 | 0.16 | 82 |
| Mathews Brothers Company — Sanford Hills Sliding Patio Door | Vinyl | 0.18 | 0.17 | 124 |
| Neuma Door — Neuma Gliding Door | Vinyl | 0.18 | 0.03 | 185 |
What other certified series does DRUTEX S.A. produce?
Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
IGLO Energy Alucover Fixed Window
U-Factor 0.14–0.20 · 10 certified options.
IGLO ENERGY Classic Fixed Window
U-Factor 0.15–0.32 · 3,527 certified options.
IGLO ENERGY Tilt and Slide Door
U-Factor 0.15–0.28 · 2,993 certified options.
MB-79N/MB-86N SI Fixed Window
U-Factor 0.15–0.32 · 2,540 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) appear below.
What thermal performance numbers separate DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) from peers?
Testing puts DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) at rank #75 of 268 Door entries with U 0.18 to 0.28 across 35 configurations. Solar heat gain ranges between 0.21 and 0.37 across Northern, North-Central, South-Central, Southern.
Can homeowners install IGLO EXT Single Swing Outward Opening Door (Full Lite Only) in cold Northern ENERGY STAR counties?
DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) supplies 21 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.
What BTU/hr heat transfer results from IGLO EXT Single Swing Outward Opening Door (Full Lite Only)'s 0.18 minimum U-Factor?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
When should a buyer skip DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) and compare alternatives?
Skip IGLO EXT Single Swing Outward Opening Door (Full Lite Only) if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO EXT Single Swing Outward Opening Door (Full Lite Only) options exceeding U 0.22.
Is IGLO EXT Single Swing Outward Opening Door (Full Lite Only) suitable for sunbelt cooling-dominated homes?
Yes. 14 Southern-certified options inside DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.37 SHGC on west-facing glass to avoid excess afternoon solar gain.
What glazing share inside IGLO EXT Single Swing Outward Opening Door (Full Lite Only) qualifies as Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 35 IGLO EXT Single Swing Outward Opening Door (Full Lite Only) options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
How do the 25C sunset and pre-1978 Lead RRP rules affect IGLO EXT Single Swing Outward Opening Door (Full Lite Only)?
Any IGLO EXT Single Swing Outward Opening Door (Full Lite Only) purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How can homeowners confirm delivered DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) units match permits?
Confirm both the paper NFRC label and permanent corner glass etch match line DRU-K-34 and NFRC ID DRU before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO EXT Single Swing Outward Opening Door (Full Lite Only) come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)