Kohltech International, Ltd. — Select Patio Door · Sliding Patio Door
With a minimum U-Factor of 0.18—-0.03 compared against the 0.21 Door median—Kohltech International, Ltd. Select Patio Door spans 5 tested options across Northern, North-Central, South-Central, Southern up to 0.26 U-Factor. Carrying NFRC CPD code KOI, the Vinyl assembly includes 2 ENERGY STAR Most Efficient packages (40.0% of line) and offers SHGC packages between 0.22 and 0.25.
- Min U-Factor
- 0.18
- SHGC Range
- 0.22-0.25
- Certified Options
- 5
- Category Standing
- #75 of 268
How does Kohltech International, Ltd. Select Patio Door compare thermally against Door peers?
Kohltech International, Ltd. Select Patio Door achieves a 0.18 thermal floor across Door lines, placing #75 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Door assemblies nationwide (median U 0.21), Select Patio Door is 0.03 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.18-0.26.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 2 configurations meet ENERGY STAR Most Efficient criteria while 5 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-09-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 5 certified glazing combinations for Select Patio Door (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 5 packages (2 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 5 packages (2 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 4 packages (2 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 4 packages (2 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Gilkey Window Company — S-7500 Patio Door | Vinyl | 0.18 | 0.16 | 16 |
| DRUTEX S.A. — IGLO EXT Single Swing Outward Opening Door (Full Lite Only) | Vinyl | 0.18 | 0.21 | 35 |
| Lindsay Windows — Freedom Door | Vinyl | 0.18 | 0.16 | 82 |
| Mathews Brothers Company — Sanford Hills Sliding Patio Door | Vinyl | 0.18 | 0.17 | 124 |
| Neuma Door — Neuma Gliding Door | Vinyl | 0.18 | 0.03 | 185 |
What other certified series does Kohltech International, Ltd. produce?
Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Fiberglass Entry Door
U-Factor 0.15–0.28 · 331,883 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. Select Patio Door appear below.
What thermal performance numbers separate Kohltech International, Ltd. Select Patio Door from peers?
Testing puts Kohltech International, Ltd. Select Patio Door at rank #75 of 268 Door entries with U 0.18 to 0.26 across 5 configurations. Solar heat gain ranges between 0.22 and 0.25 across Northern, North-Central, South-Central, Southern.
Can homeowners install Select Patio Door in cold Northern ENERGY STAR counties?
Prescriptive Northern compliance covers 5 Select Patio Door packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.
How does a 3x5 ft Select Patio Door window perform under a 40 deg F temperature drop?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Select Patio Door at U 0.18 conducts 108.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
When should a buyer skip Kohltech International, Ltd. Select Patio Door and compare alternatives?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Select Patio Door options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
Is Select Patio Door suitable for sunbelt cooling-dominated homes?
Warm-climate homeowners have 4 Southern-approved options within Select Patio Door spanning SHGC down to 0.22. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Are all 5 Select Patio Door configurations ENERGY STAR Most Efficient?
Only 2 options out of 5 (40.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kohltech International, Ltd. Select Patio Door, usually requiring triple-pane or upgraded Low-E coatings.
What 2026 federal tax credit and Lead RRP rules apply to Select Patio Door?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How can homeowners confirm delivered Kohltech International, Ltd. Select Patio Door units match permits?
Confirm both the paper NFRC label and permanent corner glass etch match line KOI-A-71 and NFRC ID KOI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. Select Patio Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)