Skip to main content
Window · Vinyl Frame NFRC DRU · Product Line DRU-K-11 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — IGLO Premier Outswing Awning · Awning (Projected)

DRUTEX S.A. engineered the IGLO Premier Outswing Awning Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 866 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.11 to 0.28 SHGC. Relative to other Vinyl models tracked under NFRC DRU, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.11-0.28
Certified Options
866
Category Standing
#742 of 1,352

How does DRUTEX S.A. IGLO Premier Outswing Awning compare thermally against Window peers?

DRUTEX S.A. IGLO Premier Outswing Awning achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IGLO Premier Outswing AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing IGLO Premier Outswing Awning (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IGLO Premier Outswing Awning Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows DRUTEX S.A. IGLO Premier Outswing Awning standing at #742 of 1,352 certified Window product series, tied with 88 others at 0.21, more insulating than 38.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.02 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.11 to 0.28) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 75 configurations meet ENERGY STAR Most Efficient criteria while 47 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2023-04-03 and v7.0 data certification on 2024-04-15. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 866 certified glazing combinations for IGLO Premier Outswing Awning (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 47 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 248 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 423 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 853 packages (75 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO Premier Outswing Awning appear below.

What U-Factor and SHGC range does DRUTEX S.A. IGLO Premier Outswing Awning achieve?

DRUTEX S.A. IGLO Premier Outswing Awning spans 866 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.11 to 0.28. Ranked #742 of 1,352 Window families, it carries 75 Most Efficient options.

Which glazing options in DRUTEX S.A. IGLO Premier Outswing Awning meet Northern climate limits?

Cold-climate buyers get 47 compliant Northern packages inside IGLO Premier Outswing Awning, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How much winter heat loss does IGLO Premier Outswing Awning conduct across a 15 sq ft opening?

At U 0.21, a standard 3x5 ft (15 sq ft) IGLO Premier Outswing Awning opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

What homeowner profiles are a poor match for DRUTEX S.A. IGLO Premier Outswing Awning?

Skip IGLO Premier Outswing Awning if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO Premier Outswing Awning options exceeding U 0.22.

How many IGLO Premier Outswing Awning glazing packages pass Southern solar-heat rules?

Yes. 853 Southern-certified options inside DRUTEX S.A. IGLO Premier Outswing Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.28 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does IGLO Premier Outswing Awning carry EPA Most Efficient certification across its lineup?

No. Exactly 75 of 866 configurations (8.7%) earn ENERGY STAR Most Efficient status in IGLO Premier Outswing Awning; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect IGLO Premier Outswing Awning?

Any IGLO Premier Outswing Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on IGLO Premier Outswing Awning?

Match the NFRC thermal sticker for code DRU and line DRU-K-11 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO Premier Outswing Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros