Window · Aluminum Frame NFRC DRU · Product Line DRU-K-29 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — MB-79N/MB-86N SI Casement Window · Casement Windows

DRUTEX S.A. engineered the MB-79N/MB-86N SI Casement Window Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 1,985 glass-spacer combinations from 0.20 to 0.32 U-Factor and 0.04 to 0.29 SHGC. Relative to other Aluminum models tracked under NFRC DRU, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.23 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.04-0.29
Certified Options
1,985
Category Standing
#671 of 1,352

How does DRUTEX S.A. MB-79N/MB-86N SI Casement Window compare thermally against Window peers?

DRUTEX S.A. MB-79N/MB-86N SI Casement Window achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. MB-79N/MB-86N SI Casement WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing MB-79N/MB-86N SI Casement Window (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

MB-79N/MB-86N SI Casement Window Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across MB-79N/MB-86N SI Casement Window spans 1,985 NFRC test records (DRU), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at -0.03 against the Aluminum median (0.23).

Mapping NFRC SHGC values (0.04 to 0.29) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 86 configurations meet ENERGY STAR Most Efficient criteria while 58 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2023-04-03 and v7.0 data certification on 2024-06-17. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.20 conducts 120.0 BTU/hr (-12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,985 certified glazing combinations for MB-79N/MB-86N SI Casement Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 58 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 546 packages (4 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 947 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,909 packages (82 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. MB-79N/MB-86N SI Casement Window appear below.

How efficient is DRUTEX S.A. MB-79N/MB-86N SI Casement Window compared with peer Window models?

Testing puts DRUTEX S.A. MB-79N/MB-86N SI Casement Window at rank #671 of 1,352 Window entries with U 0.20 to 0.32 across 1,985 configurations. Solar heat gain ranges between 0.04 and 0.29 across Northern, North-Central, South-Central, Southern.

How does DRUTEX S.A. MB-79N/MB-86N SI Casement Window satisfy Version 7.0 Northern criteria?

Yes, 58 packages satisfy Northern ENERGY STAR Version 7.0 rules in MB-79N/MB-86N SI Casement Window. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates MB-79N/MB-86N SI Casement Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip DRUTEX S.A. MB-79N/MB-86N SI Casement Window and compare alternatives?

Skip MB-79N/MB-86N SI Casement Window if local historic preservation boards prohibit Aluminum profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on MB-79N/MB-86N SI Casement Window options exceeding U 0.22.

How many MB-79N/MB-86N SI Casement Window glazing packages pass Southern solar-heat rules?

Yes, MB-79N/MB-86N SI Casement Window holds 1,909 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.04 SHGC in cooling climates.

Which package tier in MB-79N/MB-86N SI Casement Window holds Most Efficient recognition?

Within MB-79N/MB-86N SI Casement Window, 4.3% (86 of 1,985) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect MB-79N/MB-86N SI Casement Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 MB-79N/MB-86N SI Casement Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on MB-79N/MB-86N SI Casement Window?

Match the NFRC thermal sticker for code DRU and line DRU-K-29 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. MB-79N/MB-86N SI Casement Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)