Quaker Window Products — H4503 Awning · Awning (Projected)
With a minimum U-Factor of 0.20—At median compared against the 0.20 Window median—Quaker Window Products H4503 Awning spans 4,567 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code QWP, the Aluminum assembly includes 130 ENERGY STAR Most Efficient packages (2.8% of line) and offers SHGC packages between 0.12 and 0.42.
- Min U-Factor
- 0.20
- SHGC Range
- 0.12-0.42
- Certified Options
- 4,567
- Category Standing
- #671 of 1,352
How does Quaker Window Products H4503 Awning compare thermally against Window peers?
Quaker Window Products H4503 Awning achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Aluminum cohort (0.23 median U-Factor), H4503 Awning reaches 0.20 on its lowest-conductivity package — #22 of 64 in Aluminum, tied with 5 others at 0.20, more insulating than 57.8% of Aluminum lines, top 42.2% (-0.03 vs Aluminum peers). Pairing NFRC ID QWP across multi-pane fills shifts U-Factor from 0.32 down toward 0.20.
Regional qualification covers Northern, North-Central, South-Central, Southern. 130 configurations meet ENERGY STAR Most Efficient criteria while 105 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors QWP to 2026-07-21 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 120.0 BTU/hr conductive loss (-9.1% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 4,567 certified glazing combinations for H4503 Awning (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 105 packages (0 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 951 packages (4 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 1,957 packages (4 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 4,345 packages (130 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| DRUTEX S.A. — MB-79N/MB-86N SI Awning Window | Aluminum | 0.20 | 0.04 | 2,302 |
| DRUTEX S.A. — MB-79N/MB-86N SI Casement Window | Aluminum | 0.20 | 0.04 | 1,985 |
| Foshan Xiaoluban Doors and Windows Co., Ltd. — XLB-80 Dual Action Window | Aluminum | 0.20 | 0.15 | 10 |
| Andersen Corporation — Renewal by Andersen? Gliding Window | Composite | 0.20 | 0.14 | 3,535 |
| Silver Line Building Products — 70 Series (West) Awning Window | Vinyl | 0.20 | 0.11 | 5,658 |
What other certified series does Quaker Window Products produce?
Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
V300 Inswing Door
U-Factor 0.16–0.28 · 17,041 certified options.
V300/V600 Outswing Door
U-Factor 0.16–0.28 · 16,974 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products H4503 Awning appear below.
How well does H4503 Awning by Quaker Window Products insulate relative to Window benchmarks?
Quaker Window Products H4503 Awning spans 4,567 certified configurations with U-Factors between 0.20 and 0.32 and SHGC values from 0.12 to 0.42. Ranked #671 of 1,352 Window families, it carries 130 Most Efficient options.
Can homeowners install H4503 Awning in cold Northern ENERGY STAR counties?
Yes. 105 packages in Quaker Window Products H4503 Awning clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
How does a 3x5 ft H4503 Awning window perform under a 40 deg F temperature drop?
At U 0.20, a standard 3x5 ft (15 sq ft) H4503 Awning opening transfers 120.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -12.0 BTU/hr difference.
Which situations make H4503 Awning the wrong window or door choice?
Do not specify H4503 Awning without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on H4503 Awning options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
How many H4503 Awning glazing packages pass Southern solar-heat rules?
Yes. 4,345 Southern-certified options inside Quaker Window Products H4503 Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.
What glazing share inside H4503 Awning qualifies as Most Efficient?
EPA lists 130 Most Efficient options (2.8% share) inside Quaker Window Products H4503 Awning, out of 4,567 total Version 7.0 entries.
What 2026 federal tax credit and Lead RRP rules apply to H4503 Awning?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Quaker Window Products upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
What permanent glass etch marks verify H4503 Awning after sticker removal?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code QWP and product line QWP-M-147, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Quaker Window Products H4503 Awning come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)