Skip to main content
Window · Aluminum Frame NFRC DRU · Product Line DRU-K-30 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — MB-79N/MB-86N SI Awning Window · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 2,302 variants inside DRUTEX S.A. MB-79N/MB-86N SI Awning Window, combining Aluminum frame construction with U-Factors spanning 0.20 to 0.32 and SHGC 0.04 to 0.29. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #671 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.23 Btu/hr·ft²·°F median among Aluminum peers.

Min U-Factor
0.20
SHGC Range
0.04-0.29
Certified Options
2,302
Category Standing
#671 of 1,352

How does DRUTEX S.A. MB-79N/MB-86N SI Awning Window compare thermally against Window peers?

DRUTEX S.A. MB-79N/MB-86N SI Awning Window achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. MB-79N/MB-86N SI Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing MB-79N/MB-86N SI Awning Window (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

MB-79N/MB-86N SI Awning Window Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Aluminum cohort (0.23 median U-Factor), MB-79N/MB-86N SI Awning Window reaches 0.20 on its lowest-conductivity package — #22 of 64 in Aluminum, tied with 5 others at 0.20, more insulating than 57.8% of Aluminum lines, top 42.2% (-0.03 vs Aluminum peers). Pairing NFRC ID DRU across multi-pane fills shifts U-Factor from 0.32 down toward 0.20.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 200 configurations meet ENERGY STAR Most Efficient criteria while 140 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-06-17 and FENSTAR license 2023-04-03 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,302 certified glazing combinations for MB-79N/MB-86N SI Awning Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 140 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 806 packages (4 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,238 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,198 packages (196 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. MB-79N/MB-86N SI Awning Window appear below.

What U-Factor and SHGC range does DRUTEX S.A. MB-79N/MB-86N SI Awning Window achieve?

Across 2,302 tested NFRC glazing configurations, DRUTEX S.A. MB-79N/MB-86N SI Awning Window with Aluminum framing and Projected Awning (PRAW) style reaches a 0.20 minimum U-Factor and 0.04-0.29 SHGC band. It places #671 among 1,352 Window series—more insulating than 45.2%.

Can homeowners install MB-79N/MB-86N SI Awning Window in cold Northern ENERGY STAR counties?

Yes, 140 packages satisfy Northern ENERGY STAR Version 7.0 rules in MB-79N/MB-86N SI Awning Window. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for DRUTEX S.A. MB-79N/MB-86N SI Awning Window?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), MB-79N/MB-86N SI Awning Window at U 0.20 conducts 120.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip DRUTEX S.A. MB-79N/MB-86N SI Awning Window and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on MB-79N/MB-86N SI Awning Window options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many MB-79N/MB-86N SI Awning Window glazing packages pass Southern solar-heat rules?

Yes. 2,198 Southern-certified options inside DRUTEX S.A. MB-79N/MB-86N SI Awning Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.29 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in MB-79N/MB-86N SI Awning Window holds Most Efficient recognition?

Only 200 options out of 2,302 (8.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in DRUTEX S.A. MB-79N/MB-86N SI Awning Window, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect MB-79N/MB-86N SI Awning Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 MB-79N/MB-86N SI Awning Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered DRUTEX S.A. MB-79N/MB-86N SI Awning Window units match permits?

Match the NFRC thermal sticker for code DRU and line DRU-K-30 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. MB-79N/MB-86N SI Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros