Skip to main content
Door · Aluminum Frame NFRC DRU · Product Line DRU-K-33

DRUTEX S.A. — MB-79N SI+ / MB-86N SI Inswing / Outswing Door · Swinging Entry Door (Single)

DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door is a Swinging Entry Door, Single assembly with a Aluminum frame that reaches a minimum U-Factor of 0.22 across 1,315 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #145 of 268 in Door, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.04 to 0.31.

Min U-Factor
0.22
SHGC Range
0.04-0.31
Certified Options
1,315
Category Standing
#145 of 268

How does DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door compare thermally against Door peers?

DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. MB-79N SI+ / MB-86N SI Inswing / Outswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing MB-79N SI+ / MB-86N SI Inswing / Outswing Door (U 0.22).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.22430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

MB-79N SI+ / MB-86N SI Inswing / Outswing Door Cohort StandingMin U-Factor 0.22 stands at rank #145 of 268, outperforming 39.9% of peers.Min U-Factor 0.22Rank #145 of 268 (39.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door standing at #145 of 268 certified Door product series, tied with 16 others at 0.22, more insulating than 39.9% of Door lines. Comparing Aluminum profiles alone (median 0.23) shows -0.01 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 712 combinations qualify in the Northern Zone alongside 1,189 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2023-04-03 licensing and 2024-10-09 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,315 certified glazing combinations for MB-79N SI+ / MB-86N SI Inswing / Outswing Door (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 712 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 712 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,189 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,189 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Weather Shield Mfg., Inc. — 4601 Vue Outswing Door Aluminum 0.22 0.13 248
MGM Industries — 9000/9050 Sliding Glass Door Vinyl 0.22 0.14 1,317
Sierra Pacific Windows — Wood Outswing/Sidelite Wood 0.22 0.08 1,305
A Window, Inc. — PD12 Patio Door Vinyl 0.22 0.14 1,348
Sierra Pacific Windows — Wood Inswing Door Wood 0.22 0.08 1,378

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door appear below.

What U-Factor and SHGC range does DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door achieve?

Testing puts DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door at rank #145 of 268 Door entries with U 0.22 to 0.28 across 1,315 configurations. Solar heat gain ranges between 0.04 and 0.31 across Northern, North-Central, South-Central, Southern.

Which glazing options in DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door meet Northern climate limits?

Cold-climate buyers get 712 compliant Northern packages inside MB-79N SI+ / MB-86N SI Inswing / Outswing Door, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How much winter heat loss does MB-79N SI+ / MB-86N SI Inswing / Outswing Door conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on MB-79N SI+ / MB-86N SI Inswing / Outswing Door options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is MB-79N SI+ / MB-86N SI Inswing / Outswing Door suitable for sunbelt cooling-dominated homes?

Yes, MB-79N SI+ / MB-86N SI Inswing / Outswing Door holds 1,189 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.04 SHGC in cooling climates.

Which package tier in MB-79N SI+ / MB-86N SI Inswing / Outswing Door holds Most Efficient recognition?

Zero glazing builds inside MB-79N SI+ / MB-86N SI Inswing / Outswing Door's 1,315 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

How do the 25C sunset and pre-1978 Lead RRP rules affect MB-79N SI+ / MB-86N SI Inswing / Outswing Door?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current MB-79N SI+ / MB-86N SI Inswing / Outswing Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify MB-79N SI+ / MB-86N SI Inswing / Outswing Door glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code DRU and product line DRU-K-33, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. MB-79N SI+ / MB-86N SI Inswing / Outswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros