Skip to main content
Door · Aluminum Frame NFRC DRU · Product Line DRU-K-27

DRUTEX S.A. — MB-86 Fold Line HD Folding Door · Swinging Entry Door (Double)

EPA ENERGY STAR Version 7.0 certifies 11 variants inside DRUTEX S.A. MB-86 Fold Line HD Folding Door, combining Aluminum frame construction with U-Factors spanning 0.26 to 0.26 and SHGC 0.20 to 0.35. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Double family places #233 of 268 among 268 Door families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.23 Btu/hr·ft²·°F median among Aluminum peers.

Min U-Factor
0.26
SHGC Range
0.20-0.35
Certified Options
11
Category Standing
#233 of 268

How does DRUTEX S.A. MB-86 Fold Line HD Folding Door compare thermally against Door peers?

DRUTEX S.A. MB-86 Fold Line HD Folding Door achieves a 0.26 thermal floor across Door lines, placing #233 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. MB-86 Fold Line HD Folding DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing MB-86 Fold Line HD Folding Door (U 0.26).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.26100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

MB-86 Fold Line HD Folding Door Cohort StandingMin U-Factor 0.26 stands at rank #233 of 268, outperforming 7.5% of peers.Min U-Factor 0.26Rank #233 of 268 (7.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), MB-86 Fold Line HD Folding Door is 0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Aluminum frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.26-0.26.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 11 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 156.0 BTU/hr (+18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2023-04-03 and cert timestamp 2024-06-17.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11 certified glazing combinations for MB-86 Fold Line HD Folding Door (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 11 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 11 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. MB-86 Fold Line HD Folding Door appear below.

Where does DRUTEX S.A. MB-86 Fold Line HD Folding Door stand thermally among ENERGY STAR Door lines?

EPA ENERGY STAR v7.0 records 11 configurations for DRUTEX S.A. MB-86 Fold Line HD Folding Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.26 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Is MB-86 Fold Line HD Folding Door approved for Northern Zone heating climates?

Because MB-86 Fold Line HD Folding Door starts at 0.26 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 11 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

What BTU/hr heat transfer results from MB-86 Fold Line HD Folding Door's 0.26 minimum U-Factor?

Using NFRC DRU U-Factor 0.26, a 15 sq ft Hinged Patio French Door (DDFR) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).

What are the practical limitations of specifying MB-86 Fold Line HD Folding Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on MB-86 Fold Line HD Folding Door options exceeding U 0.22. Additionally, do not order Hinged Patio French Door (DDFR) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does MB-86 Fold Line HD Folding Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 2 Southern-certified options inside DRUTEX S.A. MB-86 Fold Line HD Folding Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.35 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in MB-86 Fold Line HD Folding Door holds Most Efficient recognition?

No. Zero of the 11 configurations in DRUTEX S.A. MB-86 Fold Line HD Folding Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What federal compliance checks govern 2026 MB-86 Fold Line HD Folding Door window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify MB-86 Fold Line HD Folding Door after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line DRU-K-27 and NFRC ID DRU before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. MB-86 Fold Line HD Folding Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros