Skip to main content
Door · Aluminum Frame NFRC QWP · Product Line QWP-M-132

Quaker Window Products — C200 Inswing & Outswing Door · Swinging Entry Door (Single)

Quaker Window Products engineered the C200 Inswing & Outswing Door Swinging Entry Door, Single line for Northern, North-Central, South-Central, Southern, certifying 1,390 glass-spacer combinations from 0.26 to 0.28 U-Factor and 0.11 to 0.28 SHGC. Relative to other Aluminum models tracked under NFRC QWP, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.23 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.11-0.28
Certified Options
1,390
Category Standing
#233 of 268

How does Quaker Window Products C200 Inswing & Outswing Door compare thermally against Door peers?

Quaker Window Products C200 Inswing & Outswing Door achieves a 0.26 thermal floor across Door lines, placing #233 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. C200 Inswing & Outswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing C200 Inswing & Outswing Door (U 0.26).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.26100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

C200 Inswing & Outswing Door Cohort StandingMin U-Factor 0.26 stands at rank #233 of 268, outperforming 7.5% of peers.Min U-Factor 0.26Rank #233 of 268 (7.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across C200 Inswing & Outswing Door spans 1,390 NFRC test records (QWP), ranking #233 of 268 Door families (tied with 15 others at 0.26, more insulating than 7.5% of Door lines). Its 0.26 thermal floor compares at +0.03 against the Aluminum median (0.23).

Mapping NFRC SHGC values (0.11 to 0.28) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 220 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors QWP to 2024-09-09 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 156.0 BTU/hr conductive loss (+18.2% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,390 certified glazing combinations for C200 Inswing & Outswing Door (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 220 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 220 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,336 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,336 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
ESWindows LLC — ES-LG850 Aluminum 0.26 0.12 101
DRUTEX S.A. — MB-86 Fold Line HD Folding Door Aluminum 0.26 0.20 11
Andersen Corporation — Residential Wood Entry Door - Inswing Wood 0.26 0.09 1,315
Marvin — Ultimate Wood Outswing French Door Wood 0.26 0.10 1,294
Marvin — Ultimate Wood Inswing French Door Wood 0.26 0.10 1,164

What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products C200 Inswing & Outswing Door appear below.

How well does C200 Inswing & Outswing Door by Quaker Window Products insulate relative to Door benchmarks?

EPA ENERGY STAR v7.0 records 1,390 configurations for Quaker Window Products C200 Inswing & Outswing Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.26 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

How does Quaker Window Products C200 Inswing & Outswing Door satisfy Version 7.0 Northern criteria?

With a 0.26 minimum U-Factor, Quaker Window Products C200 Inswing & Outswing Door cannot satisfy prescriptive <= 0.22 Northern targets, yet 220 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How do you calculate winter heat conduction for Quaker Window Products C200 Inswing & Outswing Door?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.26 U-Factor yields 156.0 BTU/hr conductive transfer (+18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Quaker Window Products C200 Inswing & Outswing Door for a residential project?

Do not specify C200 Inswing & Outswing Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on C200 Inswing & Outswing Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does C200 Inswing & Outswing Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 1,336 Southern-certified options inside Quaker Window Products C200 Inswing & Outswing Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.28 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in C200 Inswing & Outswing Door holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 1,390 C200 Inswing & Outswing Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Can homeowners claim Form 5695 credits on Quaker Window Products C200 Inswing & Outswing Door in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current C200 Inswing & Outswing Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Quaker Window Products C200 Inswing & Outswing Door units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line QWP-M-132 and NFRC ID QWP before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products C200 Inswing & Outswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)