Marvin — Ultimate Wood Outswing French Door · Swinging Entry Door (Double)
Marvin Ultimate Wood Outswing French Door is a Swinging Entry Door, Double assembly with a Wood frame that reaches a minimum U-Factor of 0.26 across 1,294 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #233 of 268 in Door, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.24.
- Min U-Factor
- 0.26
- SHGC Range
- 0.10-0.24
- Certified Options
- 1,294
- Category Standing
- #233 of 268
How does Marvin Ultimate Wood Outswing French Door compare thermally against Door peers?
Marvin Ultimate Wood Outswing French Door achieves a 0.26 thermal floor across Door lines, placing #233 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 105 certified Marvin series, this Swinging Entry Door, Double offers a 0.02 U-Factor adjustment span between 0.28 entry options and 0.26 top-performing glazing. Category standing is #233/268 (tied with 15 others at 0.26, more insulating than 7.5% of Door lines).
Mapping NFRC SHGC values (0.10 to 0.24) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 286 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-03-05 licensing and 2025-08-11 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,294 certified glazing combinations for Ultimate Wood Outswing French Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 286 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 286 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 1,282 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,282 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Andersen Corporation — Residential Wood Entry Door - Inswing | Wood | 0.26 | 0.09 | 1,315 |
| Andersen Corporation — E-Series Hinged Outswing Patio Door | Wood | 0.26 | 0.10 | 234 |
| Weather Shield Mfg., Inc. — 6510/6610 Swing Door | Wood | 0.26 | 0.11 | 207 |
| Windsor Windows and Doors — Pinnacle Prime French Sliding Patio Door | Wood | 0.26 | 0.12 | 71 |
| Pella Corporation — Reserve Multi-Slide | Wood | 0.26 | 0.14 | 69 |
What other certified series does Marvin produce?
Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Ultimate Direct Glaze Rectangle / Polygon
U-Factor 0.13–0.32 · 34,184 certified options.
Ultimate Wood Direct Glaze Rectangle / Polygon
U-Factor 0.13–0.32 · 13,899 certified options.
Ultimate Wood Direct Glaze Round Top
U-Factor 0.13–0.32 · 8,590 certified options.
Ultimate Wood Double Hung / Single Hung
U-Factor 0.13–0.32 · 2,649 certified options.
Ultimate Wood Double Hung / Single Hung Magnum
U-Factor 0.13–0.32 · 2,481 certified options.
Modern Direct Glaze Rectangle/Polygon
U-Factor 0.14–0.32 · 2,988 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Wood Outswing French Door appear below.
How well does Ultimate Wood Outswing French Door by Marvin insulate relative to Door benchmarks?
EPA ENERGY STAR v7.0 records 1,294 configurations for Marvin Ultimate Wood Outswing French Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.26 versus a 0.21 Door median. Only 0 options earn Most Efficient status.
Is Ultimate Wood Outswing French Door approved for Northern Zone heating climates?
Because Ultimate Wood Outswing French Door starts at 0.26 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 286 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).
How much winter heat loss does Ultimate Wood Outswing French Door conduct across a 15 sq ft opening?
At U 0.26, a standard 3x5 ft (15 sq ft) Ultimate Wood Outswing French Door opening transfers 156.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +24.0 BTU/hr difference.
What homeowner profiles are a poor match for Marvin Ultimate Wood Outswing French Door?
Skip Ultimate Wood Outswing French Door if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Wood Outswing French Door options exceeding U 0.22.
How many Ultimate Wood Outswing French Door glazing packages pass Southern solar-heat rules?
Yes, Ultimate Wood Outswing French Door holds 1,282 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.
How many Marvin Ultimate Wood Outswing French Door variants earn ENERGY STAR Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 1,294 Ultimate Wood Outswing French Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
How do the 25C sunset and pre-1978 Lead RRP rules affect Ultimate Wood Outswing French Door?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Ultimate Wood Outswing French Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC MAR and product line MAR-N-414 on delivery?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-414, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Wood Outswing French Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)