Skip to main content
Window · Vinyl Frame NFRC EWN · Product Line EWN-K-60

ESWindows LLC — ES-V500 Casement · Casement Windows

ESWindows LLC engineered the ES-V500 Casement Casement Windows line for South-Central, Southern, certifying 345 glass-spacer combinations from 0.28 to 0.32 U-Factor and 0.12 to 0.20 SHGC. Relative to other Vinyl models tracked under NFRC EWN, its minimum U-Factor is 0.09 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.28
SHGC Range
0.12-0.20
Certified Options
345
Category Standing
#1,320 of 1,352

How does ESWindows LLC ES-V500 Casement compare thermally against Window peers?

ESWindows LLC ES-V500 Casement achieves a 0.28 thermal floor across Window lines, placing #1,320 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. ES-V500 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing ES-V500 Casement (U 0.28).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.30This model: U 0.2820.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

ES-V500 Casement Cohort StandingMin U-Factor 0.28 stands at rank #1,320 of 1,352, outperforming 2.0% of peers.Min U-Factor 0.28Rank #1,320 of 1,352 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), ES-V500 Casement reaches 0.28 on its lowest-conductivity package — #984 of 1,009 in Vinyl, tied with 20 others at 0.28, more insulating than 0.5% of Vinyl lines (+0.09 vs Vinyl peers). Pairing NFRC ID EWN across multi-pane fills shifts U-Factor from 0.32 down toward 0.28.

Climate coverage for ESWindows LLC ES-V500 Casement spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.28 U-Factor yields 168.0 BTU/hr transfer (+36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2024-09-19 licensing and 2026-06-25 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 345 certified glazing combinations for ES-V500 Casement (NFRC EWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 36 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 345 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Value Windows & Doors — Galaxy Single Slider Vinyl 0.28 0.19 87
ViWinTech Window — 2100 Single Slider Vinyl 0.28 0.18 87
L.A.S. Enterprises — Weathergard II - Vinyl Single Hung Vinyl 0.28 0.14 60
All America Windows LLC — 1900 Series Single Hung Vinyl 0.28 0.19 36
Duke Vinyl Windows — Marquis Double Hung Vinyl 0.28 0.19 12

What other certified series does ESWindows LLC produce?

Compare other active ESWindows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ESWindows LLC ES-V500 Casement appear below.

How well does ES-V500 Casement by ESWindows LLC insulate relative to Window benchmarks?

ESWindows LLC ES-V500 Casement spans 345 certified configurations with U-Factors between 0.28 and 0.32 and SHGC values from 0.12 to 0.20. Ranked #1,320 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in ESWindows LLC ES-V500 Casement meet Northern climate limits?

ESWindows LLC ES-V500 Casement holds zero Northern Zone qualifications (min U 0.28). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How much winter heat loss does ES-V500 Casement conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 168.0 BTU/hr on ES-V500 Casement's lowest-U package (0.28), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What homeowner profiles are a poor match for ESWindows LLC ES-V500 Casement?

Cold-climate owners needing prescriptive U <= 0.22 should pass on ES-V500 Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in ES-V500 Casement?

Across South-Central, Southern, 345 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside ESWindows LLC ES-V500 Casement, while total line SHGC reaches 0.20 in colder packages.

Which package tier in ES-V500 Casement holds Most Efficient recognition?

All 345 ES-V500 Casement listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 ES-V500 Casement installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 ESWindows LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify ES-V500 Casement glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line EWN-K-60 and NFRC ID EWN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ESWindows LLC ES-V500 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros