Skip to main content
Window · Vinyl Frame NFRC EWN · Product Line EWN-K-61

ESWindows LLC — ES-V550 Awning · Awning (Projected)

Positioning #1,320/1,352 in certified Window, ESWindows LLC ES-V550 Awning pairs Vinyl frame construction with 336 glazing options rated between 0.12 and 0.20 SHGC across South-Central, Southern. Across 13 certified ESWindows LLC product families, its thermal resistance spans 0.28 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.28
SHGC Range
0.12-0.20
Certified Options
336
Category Standing
#1,320 of 1,352

How does ESWindows LLC ES-V550 Awning compare thermally against Window peers?

ESWindows LLC ES-V550 Awning achieves a 0.28 thermal floor across Window lines, placing #1,320 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. ES-V550 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing ES-V550 Awning (U 0.28).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.30This model: U 0.2820.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

ES-V550 Awning Cohort StandingMin U-Factor 0.28 stands at rank #1,320 of 1,352, outperforming 2.0% of peers.Min U-Factor 0.28Rank #1,320 of 1,352 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), ES-V550 Awning reaches 0.28 on its lowest-conductivity package — #984 of 1,009 in Vinyl, tied with 20 others at 0.28, more insulating than 0.5% of Vinyl lines (+0.09 vs Vinyl peers). Pairing NFRC ID EWN across multi-pane fills shifts U-Factor from 0.32 down toward 0.28.

Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.28 U-Factor yields 168.0 BTU/hr transfer (+36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2024-09-19 licensing and 2026-07-30 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 336 certified glazing combinations for ES-V550 Awning (NFRC EWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 36 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 336 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Value Windows & Doors — Galaxy Single Slider Vinyl 0.28 0.19 87
ViWinTech Window — 2100 Single Slider Vinyl 0.28 0.18 87
L.A.S. Enterprises — Weathergard II - Vinyl Single Hung Vinyl 0.28 0.14 60
All America Windows LLC — 1900 Series Single Hung Vinyl 0.28 0.19 36
Duke Vinyl Windows — Marquis Double Hung Vinyl 0.28 0.19 12

What other certified series does ESWindows LLC produce?

Compare other active ESWindows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ESWindows LLC ES-V550 Awning appear below.

Where does ESWindows LLC ES-V550 Awning stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 336 configurations for ESWindows LLC ES-V550 Awning covering South-Central, Southern, dropping down to U 0.28 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Is ES-V550 Awning approved for Northern Zone heating climates?

ESWindows LLC ES-V550 Awning holds zero Northern Zone qualifications (min U 0.28). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How do you calculate winter heat conduction for ESWindows LLC ES-V550 Awning?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), ES-V550 Awning at U 0.28 conducts 168.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose ESWindows LLC ES-V550 Awning for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on ES-V550 Awning options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does ES-V550 Awning meet Southern hot-climate SHGC caps (<= 0.23)?

Across South-Central, Southern, 336 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside ESWindows LLC ES-V550 Awning, while total line SHGC reaches 0.20 in colder packages.

Does ES-V550 Awning carry EPA Most Efficient certification across its lineup?

All 336 ES-V550 Awning listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect ES-V550 Awning?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current ES-V550 Awning retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered ESWindows LLC ES-V550 Awning units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code EWN and product line EWN-K-61, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ESWindows LLC ES-V550 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros