Skip to main content
Window · Wood Frame NFRC HII · Product Line HII-M-24

Harvey Industries, Inc. — Majesty Awning Window · Awning (Projected)

Positioning #1,292/1,352 in certified Window, Harvey Industries, Inc. Majesty Awning Window pairs Wood frame construction with 59 glazing options rated between 0.16 and 0.23 SHGC across South-Central, Southern. Across 16 certified Harvey Industries, Inc. product families, its thermal resistance spans 0.27 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.27
SHGC Range
0.16-0.23
Certified Options
59
Category Standing
#1,292 of 1,352

How does Harvey Industries, Inc. Majesty Awning Window compare thermally against Window peers?

Harvey Industries, Inc. Majesty Awning Window achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Majesty Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Majesty Awning Window (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Majesty Awning Window Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Harvey Industries, Inc. Majesty Awning Window at rank #1,292 of 1,352 (tied with 27 others at 0.27, more insulating than 2.4% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.16-0.23 band.

Climate coverage for Harvey Industries, Inc. Majesty Awning Window spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2025-08-20.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 59 certified glazing combinations for Majesty Awning Window (NFRC HII) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 10 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 59 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Harvey Industries, Inc. produce?

Compare other active Harvey Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Harvey Industries, Inc. Majesty Awning Window appear below.

How well does Majesty Awning Window by Harvey Industries, Inc. insulate relative to Window benchmarks?

Harvey Industries, Inc. Majesty Awning Window spans 59 certified configurations with U-Factors between 0.27 and 0.32 and SHGC values from 0.16 to 0.23. Ranked #1,292 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Harvey Industries, Inc. Majesty Awning Window meet Northern climate limits?

Harvey Industries, Inc. Majesty Awning Window holds zero Northern Zone qualifications (min U 0.27). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How do you calculate winter heat conduction for Harvey Industries, Inc. Majesty Awning Window?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Majesty Awning Window at U 0.27 conducts 162.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Harvey Industries, Inc. Majesty Awning Window for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Majesty Awning Window options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Majesty Awning Window glazing packages pass Southern solar-heat rules?

Exactly 59 Majesty Awning Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.16 rather than higher 0.23 glass.

Are all 59 Majesty Awning Window configurations ENERGY STAR Most Efficient?

No. Zero of the 59 configurations in Harvey Industries, Inc. Majesty Awning Window hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Can homeowners claim Form 5695 credits on Harvey Industries, Inc. Majesty Awning Window in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Harvey Industries, Inc. Majesty Awning Window units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line HII-M-24 and NFRC ID HII before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Harvey Industries, Inc. Majesty Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros