Skip to main content
Window · Wood Frame NFRC TVW · Product Line TVW-A-162

Lincoln Wood Products, Inc. — Clad Hybrid Awning - Push-Out & Crank-Out · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 40 variants inside Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out, combining Wood frame construction with U-Factors spanning 0.27 to 0.32 and SHGC 0.16 to 0.23. Qualifying for South-Central, Southern, this Awning, Projected family places #1,292 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.27
SHGC Range
0.16-0.23
Certified Options
40
Category Standing
#1,292 of 1,352

How does Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out compare thermally against Window peers?

Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Clad Hybrid Awning - Push-Out & Crank-OutHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Clad Hybrid Awning - Push-Out & Crank-Out (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Clad Hybrid Awning - Push-Out & Crank-Out Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 18 certified Lincoln Wood Products, Inc. series, this Awning, Projected offers a 0.05 U-Factor adjustment span between 0.32 entry options and 0.27 top-performing glazing. Category standing is #1,292/1,352 (tied with 27 others at 0.27, more insulating than 2.4% of Window lines).

Climate coverage for Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Lifecycle documentation anchors TVW to 2024-04-09 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 162.0 BTU/hr conductive loss (+22.7% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 40 certified glazing combinations for Clad Hybrid Awning - Push-Out & Crank-Out (NFRC TVW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 9 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 40 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lincoln Wood Products, Inc. produce?

Compare other active Lincoln Wood Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out appear below.

How well does Clad Hybrid Awning - Push-Out & Crank-Out by Lincoln Wood Products, Inc. insulate relative to Window benchmarks?

Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out spans 40 certified configurations with U-Factors between 0.27 and 0.32 and SHGC values from 0.16 to 0.23. Ranked #1,292 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out meet Northern climate limits?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.27). Focus on South-Central, Southern glazing applications where SHGC 0.16-0.23 manages cooling loads.

What conductive BTU/hr difference separates Clad Hybrid Awning - Push-Out & Crank-Out from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Clad Hybrid Awning - Push-Out & Crank-Out at U 0.27 conducts 162.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out and compare alternatives?

Do not specify Clad Hybrid Awning - Push-Out & Crank-Out without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Clad Hybrid Awning - Push-Out & Crank-Out options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out in Southern or South-Central zones?

Yes. 40 Southern-certified options inside Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside Clad Hybrid Awning - Push-Out & Crank-Out qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 40 Clad Hybrid Awning - Push-Out & Crank-Out options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect Clad Hybrid Awning - Push-Out & Crank-Out?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on Clad Hybrid Awning - Push-Out & Crank-Out?

Inspectors match the temporary NFRC sticker (U 0.27-0.32, SHGC 0.16-0.23) against permit drawings for line TVW-A-162. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lincoln Wood Products, Inc. Clad Hybrid Awning - Push-Out & Crank-Out come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros