Windsor Windows and Doors — Revive Clad Pocket Double Hung · Double Hung
Windsor Windows and Doors Revive Clad Pocket Double Hung is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.27 across 241 certified glazing configurations covering South-Central, Southern. Ranked #1,292 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.23.
- Min U-Factor
- 0.27
- SHGC Range
- 0.11-0.23
- Certified Options
- 241
- Category Standing
- #1,292 of 1,352
How does Windsor Windows and Doors Revive Clad Pocket Double Hung compare thermally against Window peers?
Windsor Windows and Doors Revive Clad Pocket Double Hung achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), Revive Clad Pocket Double Hung reaches 0.27 on its lowest-conductivity package — #377 of 408 in Wood, tied with 17 others at 0.27, more insulating than 3.4% of Wood lines (+0.06 vs Wood peers). Pairing NFRC ID WIN across multi-pane fills shifts U-Factor from 0.32 down toward 0.27.
Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.
Data provenance links certification 2025-10-10 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 162.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 241 certified glazing combinations for Revive Clad Pocket Double Hung (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 18 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 241 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Andersen Corporation — E-Series Hinged Outswing Patio Door Venting Sidelight | Wood | 0.27 | 0.10 | 226 |
| JELD-WEN, inc. — Custom Clad Horizontal Sliding Window | Wood | 0.27 | 0.12 | 262 |
| Weather Shield Mfg., Inc. — 8401 Horizontal Slider | Wood | 0.27 | 0.11 | 198 |
| Andersen Corporation — Residential Wood Entry Door Sidelight - Inswing | Wood | 0.27 | 0.08 | 306 |
| JELD-WEN, inc. — Custom Clad Double Hung | Wood | 0.27 | 0.11 | 308 |
What other certified series does Windsor Windows and Doors produce?
Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Pinnacle Clad Radius Direct Glaze
U-Factor 0.15–0.32 · 1,266 certified options.
Next Dimension Casement Picture
U-Factor 0.17–0.32 · 1,610 certified options.
Pinnacle Clad Direct Set 3.25" Frame
U-Factor 0.17–0.32 · 817 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Revive Clad Pocket Double Hung appear below.
What U-Factor and SHGC range does Windsor Windows and Doors Revive Clad Pocket Double Hung achieve?
Across 241 tested NFRC glazing configurations, Windsor Windows and Doors Revive Clad Pocket Double Hung with Wood framing and Double-Hung (VSDH) style reaches a 0.27 minimum U-Factor and 0.11-0.23 SHGC band. It places #1,292 among 1,352 Window series—more insulating than 2.4%.
Does Windsor Windows and Doors Revive Clad Pocket Double Hung qualify for the ENERGY STAR Northern Zone?
Northern Zone certification is absent for Revive Clad Pocket Double Hung (0 qualifying options, min U 0.27). Install this Double-Hung (VSDH) product only within South-Central, Southern regions where lower SHGC caps apply.
How does a 3x5 ft Revive Clad Pocket Double Hung window perform under a 40 deg F temperature drop?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Revive Clad Pocket Double Hung at U 0.27 conducts 162.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Which situations make Revive Clad Pocket Double Hung the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Revive Clad Pocket Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many Revive Clad Pocket Double Hung glazing packages pass Southern solar-heat rules?
Yes, Revive Clad Pocket Double Hung holds 241 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.
Which package tier in Revive Clad Pocket Double Hung holds Most Efficient recognition?
ENERGY STAR Most Efficient designation is absent across all 241 Revive Clad Pocket Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What 2026 federal tax credit and Lead RRP rules apply to Revive Clad Pocket Double Hung?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Windsor Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
Where are NFRC and IGCC identification marks located on Revive Clad Pocket Double Hung?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIN and product line WIN-N-167, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Revive Clad Pocket Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)