Andersen Corporation — E-Series Hinged Outswing Patio Door Venting Sidelight · Sidelite
EPA ENERGY STAR Version 7.0 certifies 226 variants inside Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight, combining Wood frame construction with U-Factors spanning 0.27 to 0.28 and SHGC 0.10 to 0.22. Qualifying for South-Central, Southern, this Sidelite family places #1,292 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.
- Min U-Factor
- 0.27
- SHGC Range
- 0.10-0.22
- Certified Options
- 226
- Category Standing
- #1,292 of 1,352
How does Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight compare thermally against Window peers?
Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), E-Series Hinged Outswing Patio Door Venting Sidelight reaches 0.27 on its lowest-conductivity package — #377 of 408 in Wood, tied with 17 others at 0.27, more insulating than 3.4% of Wood lines (+0.06 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.28 down toward 0.27.
Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.10 lowers cooling load.
Data provenance links certification 2024-04-09 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 162.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 226 certified glazing combinations for E-Series Hinged Outswing Patio Door Venting Sidelight (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 226 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 226 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Revive Clad Pocket Double Hung | Wood | 0.27 | 0.11 | 241 |
| Weather Shield Mfg., Inc. — 8401 Horizontal Slider | Wood | 0.27 | 0.11 | 198 |
| JELD-WEN, inc. — Custom Clad Horizontal Sliding Window | Wood | 0.27 | 0.12 | 262 |
| JELD-WEN, inc. — Custom Clad Double Hung | Wood | 0.27 | 0.11 | 308 |
| Harvey Industries, Inc. — Majesty Awning Window | Wood | 0.27 | 0.16 | 59 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight appear below.
Where does Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight stand thermally among ENERGY STAR Window lines?
Testing puts Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight at rank #1,292 of 1,352 Window entries with U 0.27 to 0.28 across 226 configurations. Solar heat gain ranges between 0.10 and 0.22 across South-Central, Southern.
Does Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight qualify for the ENERGY STAR Northern Zone?
No. Because E-Series Hinged Outswing Patio Door Venting Sidelight reaches only 0.27 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across South-Central, Southern cooling or mixed markets.
How much winter heat loss does E-Series Hinged Outswing Patio Door Venting Sidelight conduct across a 15 sq ft opening?
At U 0.27, a standard 3x5 ft (15 sq ft) E-Series Hinged Outswing Patio Door Venting Sidelight opening transfers 162.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +30.0 BTU/hr difference.
Who should NOT choose Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight for a residential project?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Hinged Outswing Patio Door Venting Sidelight options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.
What Southern ENERGY STAR v7.0 options exist in E-Series Hinged Outswing Patio Door Venting Sidelight?
Across South-Central, Southern, 226 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight, while total line SHGC reaches 0.22 in colder packages.
What glazing share inside E-Series Hinged Outswing Patio Door Venting Sidelight qualifies as Most Efficient?
Zero glazing builds inside E-Series Hinged Outswing Patio Door Venting Sidelight's 226 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
How do the 25C sunset and pre-1978 Lead RRP rules affect E-Series Hinged Outswing Patio Door Venting Sidelight?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current E-Series Hinged Outswing Patio Door Venting Sidelight retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
What permanent glass etch marks verify E-Series Hinged Outswing Patio Door Venting Sidelight after sticker removal?
Match the NFRC thermal sticker for code AND and line AND-N-164 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Hinged Outswing Patio Door Venting Sidelight come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)