JELD-WEN, inc. — Custom Clad Horizontal Sliding Window · Single Slider
Across 61 JELD-WEN, inc. certified families, Custom Clad Horizontal Sliding Window supplies 262 Single Slider configurations starting at 0.27 U-Factor and 0.12 SHGC for South-Central, Southern, reaching up to 0.32 U-Factor and 0.23 SHGC. Its thermal floor ranks #1,292 of 1,352 category entries—0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.27
- SHGC Range
- 0.12-0.23
- Certified Options
- 262
- Category Standing
- #1,292 of 1,352
How does JELD-WEN, inc. Custom Clad Horizontal Sliding Window compare thermally against Window peers?
JELD-WEN, inc. Custom Clad Horizontal Sliding Window achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), Custom Clad Horizontal Sliding Window reaches 0.27 on its lowest-conductivity package — #377 of 408 in Wood, tied with 17 others at 0.27, more insulating than 3.4% of Wood lines (+0.06 vs Wood peers). Pairing NFRC ID JEL across multi-pane fills shifts U-Factor from 0.32 down toward 0.27.
Regional qualification covers South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.27 U-Factor yields 162.0 BTU/hr transfer (+30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-08-08 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 262 certified glazing combinations for Custom Clad Horizontal Sliding Window (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 21 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 262 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Revive Clad Pocket Double Hung | Wood | 0.27 | 0.11 | 241 |
| Andersen Corporation — E-Series Hinged Outswing Patio Door Venting Sidelight | Wood | 0.27 | 0.10 | 226 |
| Andersen Corporation — Residential Wood Entry Door Sidelight - Inswing | Wood | 0.27 | 0.08 | 306 |
| Weather Shield Mfg., Inc. — 8401 Horizontal Slider | Wood | 0.27 | 0.11 | 198 |
| Harvey Industries, Inc. — Majesty Awning Window | Wood | 0.27 | 0.16 | 59 |
What other certified series does JELD-WEN, inc. produce?
Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
7500 Series Horizontal Slider
U-Factor 0.14–0.32 · 42,001 certified options.
Premium Vinyl (V-4500) Casement Fixed Direct Set
U-Factor 0.14–0.32 · 2,573 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom Clad Horizontal Sliding Window appear below.
What thermal performance numbers separate JELD-WEN, inc. Custom Clad Horizontal Sliding Window from peers?
Testing puts JELD-WEN, inc. Custom Clad Horizontal Sliding Window at rank #1,292 of 1,352 Window entries with U 0.27 to 0.32 across 262 configurations. Solar heat gain ranges between 0.12 and 0.23 across South-Central, Southern.
Which glazing options in JELD-WEN, inc. Custom Clad Horizontal Sliding Window meet Northern climate limits?
No. Because Custom Clad Horizontal Sliding Window reaches only 0.27 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across South-Central, Southern cooling or mixed markets.
How much winter heat loss does Custom Clad Horizontal Sliding Window conduct across a 15 sq ft opening?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Custom Clad Horizontal Sliding Window at U 0.27 conducts 162.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose JELD-WEN, inc. Custom Clad Horizontal Sliding Window for a residential project?
Do not specify Custom Clad Horizontal Sliding Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom Clad Horizontal Sliding Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Can you install JELD-WEN, inc. Custom Clad Horizontal Sliding Window in Southern or South-Central zones?
Yes. 262 Southern-certified options inside JELD-WEN, inc. Custom Clad Horizontal Sliding Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in Custom Clad Horizontal Sliding Window holds Most Efficient recognition?
Custom Clad Horizontal Sliding Window holds zero Most Efficient entries across its 262 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.
Can homeowners claim Form 5695 credits on JELD-WEN, inc. Custom Clad Horizontal Sliding Window in 2026?
Any Custom Clad Horizontal Sliding Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do you cross-check NFRC JEL and product line JEL-N-175 on delivery?
Verify NFRC ID JEL and series JEL-N-175 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom Clad Horizontal Sliding Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)