Weather Shield Mfg., Inc. — 8401 Horizontal Slider · Double Slider
With a minimum U-Factor of 0.27—+0.07 compared against the 0.20 Window median—Weather Shield Mfg., Inc. 8401 Horizontal Slider spans 198 tested options across South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code WEA, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.11 and 0.23.
- Min U-Factor
- 0.27
- SHGC Range
- 0.11-0.23
- Certified Options
- 198
- Category Standing
- #1,292 of 1,352
How does Weather Shield Mfg., Inc. 8401 Horizontal Slider compare thermally against Window peers?
Weather Shield Mfg., Inc. 8401 Horizontal Slider achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 8401 Horizontal Slider is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.27-0.32.
Climate coverage for Weather Shield Mfg., Inc. 8401 Horizontal Slider spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2026-02-12.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 198 certified glazing combinations for 8401 Horizontal Slider (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 21 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 198 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Andersen Corporation — E-Series Hinged Outswing Patio Door Venting Sidelight | Wood | 0.27 | 0.10 | 226 |
| Windsor Windows and Doors — Revive Clad Pocket Double Hung | Wood | 0.27 | 0.11 | 241 |
| JELD-WEN, inc. — Custom Clad Horizontal Sliding Window | Wood | 0.27 | 0.12 | 262 |
| Andersen Corporation — Residential Wood Entry Door Sidelight - Inswing | Wood | 0.27 | 0.08 | 306 |
| JELD-WEN, inc. — Custom Clad Double Hung | Wood | 0.27 | 0.11 | 308 |
What other certified series does Weather Shield Mfg., Inc. produce?
Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8306 / 1309 / 1310 Direct Set
U-Factor 0.16–0.32 · 1,033 certified options.
8211/8216/1209/1210 Premium Casement Picture
U-Factor 0.17–0.32 · 885 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 8401 Horizontal Slider appear below.
How efficient is Weather Shield Mfg., Inc. 8401 Horizontal Slider compared with peer Window models?
Testing puts Weather Shield Mfg., Inc. 8401 Horizontal Slider at rank #1,292 of 1,352 Window entries with U 0.27 to 0.32 across 198 configurations. Solar heat gain ranges between 0.11 and 0.23 across South-Central, Southern.
Can homeowners install 8401 Horizontal Slider in cold Northern ENERGY STAR counties?
Weather Shield Mfg., Inc. 8401 Horizontal Slider holds zero Northern Zone qualifications (min U 0.27). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.
What BTU/hr heat transfer results from 8401 Horizontal Slider's 0.27 minimum U-Factor?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 8401 Horizontal Slider at U 0.27 conducts 162.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying 8401 Horizontal Slider?
Do not specify 8401 Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 8401 Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Is 8401 Horizontal Slider suitable for sunbelt cooling-dominated homes?
Yes, 8401 Horizontal Slider holds 198 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.
Does 8401 Horizontal Slider carry EPA Most Efficient certification across its lineup?
No. Zero of the 198 configurations in Weather Shield Mfg., Inc. 8401 Horizontal Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
Do 2026 8401 Horizontal Slider installations qualify for IRS Section 25C tax credits?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Weather Shield Mfg., Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify 8401 Horizontal Slider glass specs on job sites?
Confirm both the paper NFRC label and permanent corner glass etch match line WEA-N-250 and NFRC ID WEA before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 8401 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)