Skip to main content
Window · Wood Frame NFRC HII · Product Line HII-M-26

Harvey Industries, Inc. — Majesty Double Hung · Double Hung

Harvey Industries, Inc. Majesty Double Hung is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.27 across 54 certified glazing configurations covering South-Central, Southern. Ranked #1,292 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.23.

Min U-Factor
0.27
SHGC Range
0.16-0.23
Certified Options
54
Category Standing
#1,292 of 1,352

How does Harvey Industries, Inc. Majesty Double Hung compare thermally against Window peers?

Harvey Industries, Inc. Majesty Double Hung achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Majesty Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Majesty Double Hung (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Majesty Double Hung Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Harvey Industries, Inc. Majesty Double Hung standing at #1,292 of 1,352 certified Window product series, tied with 27 others at 0.27, more insulating than 2.4% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.06 before selecting Low-E tiers.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Data provenance links certification 2025-01-13 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 162.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 54 certified glazing combinations for Majesty Double Hung (NFRC HII) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 24 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 54 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Harvey Industries, Inc. produce?

Compare other active Harvey Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Harvey Industries, Inc. Majesty Double Hung appear below.

What thermal performance numbers separate Harvey Industries, Inc. Majesty Double Hung from peers?

Testing puts Harvey Industries, Inc. Majesty Double Hung at rank #1,292 of 1,352 Window entries with U 0.27 to 0.32 across 54 configurations. Solar heat gain ranges between 0.16 and 0.23 across South-Central, Southern.

Which glazing options in Harvey Industries, Inc. Majesty Double Hung meet Northern climate limits?

Northern Zone certification is absent for Majesty Double Hung (0 qualifying options, min U 0.27). Install this Double-Hung (VSDH) product only within South-Central, Southern regions where lower SHGC caps apply.

How do you calculate winter heat conduction for Harvey Industries, Inc. Majesty Double Hung?

Using NFRC HII U-Factor 0.27, a 15 sq ft Double-Hung (VSDH) assembly conducts 162.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+30.0 BTU/hr margin).

What are the practical limitations of specifying Majesty Double Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Majesty Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Can you install Harvey Industries, Inc. Majesty Double Hung in Southern or South-Central zones?

Yes, Majesty Double Hung holds 54 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

How many Harvey Industries, Inc. Majesty Double Hung variants earn ENERGY STAR Most Efficient?

All 54 Majesty Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Can homeowners claim Form 5695 credits on Harvey Industries, Inc. Majesty Double Hung in 2026?

Any Majesty Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC HII and product line HII-M-26 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line HII-M-26 and NFRC ID HII before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Harvey Industries, Inc. Majesty Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros