Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-176

JELD-WEN, inc. — Builders Vinyl (V-2500) Horizontal Slider · Single Slider

EPA ENERGY STAR Version 7.0 certifies 29,395 variants inside JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider, combining Vinyl frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.09 to 0.54. Qualifying for Northern, North-Central, South-Central, Southern, this Single Slider family places #1,034 of 1,352 among 1,352 Window families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.24
SHGC Range
0.09-0.54
Certified Options
29,395
Category Standing
#1,034 of 1,352

How does JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider compare thermally against Window peers?

JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Builders Vinyl (V-2500) Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Builders Vinyl (V-2500) Horizontal Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Builders Vinyl (V-2500) Horizontal Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 1,107 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-03-12 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 29,395 certified glazing combinations for Builders Vinyl (V-2500) Horizontal Slider (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 1,107 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 3,095 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 6,352 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 26,565 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider appear below.

What U-Factor and SHGC range does JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider achieve?

EPA ENERGY STAR v7.0 records 29,395 configurations for JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider qualify for the ENERGY STAR Northern Zone?

With a 0.24 minimum U-Factor, JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider cannot satisfy prescriptive <= 0.22 Northern targets, yet 1,107 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

What conductive BTU/hr difference separates Builders Vinyl (V-2500) Horizontal Slider from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Builders Vinyl (V-2500) Horizontal Slider at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make Builders Vinyl (V-2500) Horizontal Slider the wrong window or door choice?

Skip Builders Vinyl (V-2500) Horizontal Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Builders Vinyl (V-2500) Horizontal Slider options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Builders Vinyl (V-2500) Horizontal Slider?

Yes. 26,565 Southern-certified options inside JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.54 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 29,395 Builders Vinyl (V-2500) Horizontal Slider configurations ENERGY STAR Most Efficient?

Builders Vinyl (V-2500) Horizontal Slider holds zero Most Efficient entries across its 29,395 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Do 2026 Builders Vinyl (V-2500) Horizontal Slider installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Builders Vinyl (V-2500) Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line JEL-A-176 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Builders Vinyl (V-2500) Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros