Wincore Window Company, LLC — 400, 500, 5400 Single Hung Window · Single Hung
Wincore Window Company, LLC engineered the 400, 500, 5400 Single Hung Window Single Hung line for Northern, North-Central, South-Central, Southern, certifying 12,231 glass-spacer combinations from 0.24 to 0.32 U-Factor and 0.13 to 0.52 SHGC. Relative to other Vinyl models tracked under NFRC WCW, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.24
- SHGC Range
- 0.13-0.52
- Certified Options
- 12,231
- Category Standing
- #1,034 of 1,352
How does Wincore Window Company, LLC 400, 500, 5400 Single Hung Window compare thermally against Window peers?
Wincore Window Company, LLC 400, 500, 5400 Single Hung Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), 400, 500, 5400 Single Hung Window reaches 0.24 on its lowest-conductivity package — #798 of 1,009 in Vinyl, tied with 108 others at 0.24, more insulating than 10.2% of Vinyl lines (+0.05 vs Vinyl peers). Pairing NFRC ID WCW across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.
Climate coverage for Wincore Window Company, LLC 400, 500, 5400 Single Hung Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 170 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2025-04-24. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 12,231 certified glazing combinations for 400, 500, 5400 Single Hung Window (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 170 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 514 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 4,050 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 12,061 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Milgard Manufacturing, Inc. — 2410T/2411T/2430T/2470T Awning | Vinyl | 0.24 | 0.09 | 9,775 |
| JELD-WEN, inc. — Builders Vinyl (V-2500) Side Load Single Hung | Vinyl | 0.24 | 0.13 | 8,836 |
| Milgard Manufacturing, Inc. — 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning | Vinyl | 0.24 | 0.09 | 7,335 |
| Milgard Manufacturing, Inc. — 2110.2111.2130.2130J.2170 HS | Vinyl | 0.24 | 0.09 | 5,703 |
| Milgard Manufacturing, Inc. — 2210.2211.2230.2230J.2270 Vertical Slider | Vinyl | 0.24 | 0.09 | 5,484 |
What other certified series does Wincore Window Company, LLC produce?
Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
7700, 8400, 8800 Picture Window
U-Factor 0.14–0.32 · 28,216 certified options.
5400, 7700 Casement Picture Window
U-Factor 0.15–0.32 · 16,031 certified options.
9400, 9700, 8800, 9800 Single Hung
U-Factor 0.15–0.32 · 189,040 certified options.
Fiberglass Entry Door
U-Factor 0.16–0.28 · 11,717 certified options.
5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window
U-Factor 0.17–0.32 · 6,278 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC 400, 500, 5400 Single Hung Window appear below.
What thermal performance numbers separate Wincore Window Company, LLC 400, 500, 5400 Single Hung Window from peers?
Wincore Window Company, LLC 400, 500, 5400 Single Hung Window spans 12,231 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.13 to 0.52. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.
Is 400, 500, 5400 Single Hung Window approved for Northern Zone heating climates?
Because 400, 500, 5400 Single Hung Window starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 170 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).
What conductive BTU/hr difference separates 400, 500, 5400 Single Hung Window from the 0.22 Northern rule?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 400, 500, 5400 Single Hung Window's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
Which situations make 400, 500, 5400 Single Hung Window the wrong window or door choice?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400, 500, 5400 Single Hung Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
Is 400, 500, 5400 Single Hung Window suitable for sunbelt cooling-dominated homes?
Yes. 12,061 Southern-certified options inside Wincore Window Company, LLC 400, 500, 5400 Single Hung Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.52 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in 400, 500, 5400 Single Hung Window holds Most Efficient recognition?
ENERGY STAR Most Efficient designation is absent across all 12,231 400, 500, 5400 Single Hung Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What 2026 federal tax credit and Lead RRP rules apply to 400, 500, 5400 Single Hung Window?
Any 400, 500, 5400 Single Hung Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do building inspectors verify 400, 500, 5400 Single Hung Window glass specs on job sites?
Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.13-0.52) against permit drawings for line WCW-M-35. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC 400, 500, 5400 Single Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)