Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-225

JELD-WEN, inc. — Builders Vinyl (V-2500) Tilt Single Hung · Single Hung

Positioning #1,034/1,352 in certified Window, JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung pairs Vinyl frame construction with 5,460 glazing options rated between 0.14 and 0.54 SHGC across Northern, North-Central, South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.24 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.14-0.54
Certified Options
5,460
Category Standing
#1,034 of 1,352

How does JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung compare thermally against Window peers?

JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Builders Vinyl (V-2500) Tilt Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Builders Vinyl (V-2500) Tilt Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Builders Vinyl (V-2500) Tilt Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 188 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-06-04 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,460 certified glazing combinations for Builders Vinyl (V-2500) Tilt Single Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 188 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 738 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,053 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 4,802 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung appear below.

Where does JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 5,460 configurations for JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung qualify for the ENERGY STAR Northern Zone?

While JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung misses the <= 0.22 prescriptive mark (floor U 0.24), 188 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How much winter heat loss does Builders Vinyl (V-2500) Tilt Single Hung conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Builders Vinyl (V-2500) Tilt Single Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make Builders Vinyl (V-2500) Tilt Single Hung the wrong window or door choice?

Skip Builders Vinyl (V-2500) Tilt Single Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Builders Vinyl (V-2500) Tilt Single Hung options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Builders Vinyl (V-2500) Tilt Single Hung?

Yes. 4,802 Southern-certified options inside JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.54 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does Builders Vinyl (V-2500) Tilt Single Hung carry EPA Most Efficient certification across its lineup?

Builders Vinyl (V-2500) Tilt Single Hung holds zero Most Efficient entries across its 5,460 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 JELD-WEN, inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on Builders Vinyl (V-2500) Tilt Single Hung?

Confirm both the paper NFRC label and permanent corner glass etch match line JEL-A-225 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Builders Vinyl (V-2500) Tilt Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)