Skip to main content
Window · Wood Frame NFRC JEL · Product Line JEL-N-789

JELD-WEN, inc. — Custom Clad Epic Double Hung · Double Hung

JELD-WEN, inc. Custom Clad Epic Double Hung is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.25 across 387 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.23.

Min U-Factor
0.25
SHGC Range
0.10-0.23
Certified Options
387
Category Standing
#1,174 of 1,352

How does JELD-WEN, inc. Custom Clad Epic Double Hung compare thermally against Window peers?

JELD-WEN, inc. Custom Clad Epic Double Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Custom Clad Epic Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Custom Clad Epic Double Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Custom Clad Epic Double Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows JELD-WEN, inc. Custom Clad Epic Double Hung standing at #1,174 of 1,352 certified Window product series, tied with 81 others at 0.25, more insulating than 7.2% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.04 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.10 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-04-18 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 387 certified glazing combinations for Custom Clad Epic Double Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 2 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 35 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 387 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom Clad Epic Double Hung appear below.

Where does JELD-WEN, inc. Custom Clad Epic Double Hung stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 387 configurations for JELD-WEN, inc. Custom Clad Epic Double Hung covering North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Is Custom Clad Epic Double Hung approved for Northern Zone heating climates?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.25). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.10-0.23 manages cooling loads.

What BTU/hr heat transfer results from Custom Clad Epic Double Hung's 0.25 minimum U-Factor?

At U 0.25, a standard 3x5 ft (15 sq ft) Custom Clad Epic Double Hung opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

Which situations make Custom Clad Epic Double Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom Clad Epic Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is Custom Clad Epic Double Hung suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 387 Southern-approved options within Custom Clad Epic Double Hung spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 387 Custom Clad Epic Double Hung configurations ENERGY STAR Most Efficient?

All 387 Custom Clad Epic Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Can homeowners claim Form 5695 credits on JELD-WEN, inc. Custom Clad Epic Double Hung in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Custom Clad Epic Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on Custom Clad Epic Double Hung?

Match the NFRC thermal sticker for code JEL and line JEL-N-789 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom Clad Epic Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros