Andersen Corporation — 200 Series Tilt-Wash Double Hung Window · Double Hung
EPA ENERGY STAR Version 7.0 certifies 381 variants inside Andersen Corporation 200 Series Tilt-Wash Double Hung Window, combining Wood frame construction with U-Factors spanning 0.25 to 0.32 and SHGC 0.14 to 0.48. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #1,174 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.
- Min U-Factor
- 0.25
- SHGC Range
- 0.14-0.48
- Certified Options
- 381
- Category Standing
- #1,174 of 1,352
How does Andersen Corporation 200 Series Tilt-Wash Double Hung Window compare thermally against Window peers?
Andersen Corporation 200 Series Tilt-Wash Double Hung Window achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 200 Series Tilt-Wash Double Hung Window is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.25-0.32.
Climate coverage for Andersen Corporation 200 Series Tilt-Wash Double Hung Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-04-11.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 381 certified glazing combinations for 200 Series Tilt-Wash Double Hung Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 16 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 84 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 377 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Casement | Wood | 0.25 | 0.15 | 385 |
| JELD-WEN, inc. — Custom Clad Epic Double Hung | Wood | 0.25 | 0.10 | 387 |
| Windsor Windows and Doors — Pinnacle Clad Casement 3.25" Frame | Wood | 0.25 | 0.15 | 371 |
| JELD-WEN, inc. — Custom Wood Horizontal Sliding Window | Wood | 0.25 | 0.11 | 393 |
| Windsor Windows and Doors — Pinnacle Clad Awning | Wood | 0.25 | 0.15 | 362 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 200 Series Tilt-Wash Double Hung Window appear below.
Where does Andersen Corporation 200 Series Tilt-Wash Double Hung Window stand thermally among ENERGY STAR Window lines?
EPA ENERGY STAR v7.0 records 381 configurations for Andersen Corporation 200 Series Tilt-Wash Double Hung Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.
Can homeowners install 200 Series Tilt-Wash Double Hung Window in cold Northern ENERGY STAR counties?
Because 200 Series Tilt-Wash Double Hung Window starts at 0.25 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 4 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).
What BTU/hr heat transfer results from 200 Series Tilt-Wash Double Hung Window's 0.25 minimum U-Factor?
At U 0.25, a standard 3x5 ft (15 sq ft) 200 Series Tilt-Wash Double Hung Window opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.
Which situations make 200 Series Tilt-Wash Double Hung Window the wrong window or door choice?
Skip 200 Series Tilt-Wash Double Hung Window if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 200 Series Tilt-Wash Double Hung Window options exceeding U 0.22.
How many 200 Series Tilt-Wash Double Hung Window glazing packages pass Southern solar-heat rules?
Yes, 200 Series Tilt-Wash Double Hung Window holds 377 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.
How many Andersen Corporation 200 Series Tilt-Wash Double Hung Window variants earn ENERGY STAR Most Efficient?
All 381 200 Series Tilt-Wash Double Hung Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
How do the 25C sunset and pre-1978 Lead RRP rules affect 200 Series Tilt-Wash Double Hung Window?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do you cross-check NFRC AND and product line AND-N-59 on delivery?
Inspectors match the temporary NFRC sticker (U 0.25-0.32, SHGC 0.14-0.48) against permit drawings for line AND-N-59. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 200 Series Tilt-Wash Double Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)